Electronic Components Datasheet Search
  English  ▼

X  

11974 Datasheet(PDF) 4 Page - Agilent(Hewlett-Packard)

Part # 11974
Description  Preselected Millimeter Mixers RF Sections Available in Four Bands from 26.5 to 75 GHz
PDF  8 Pages
Scroll/Zoom Zoom In 100%  Zoom Out
Manufacturer  HP [Agilent(Hewlett-Packard)]
Direct Link  http://www.home.agilent.com
Logo HP - Agilent(Hewlett-Packard)

11974 Datasheet(HTML) 4 Page - Agilent(Hewlett-Packard)

  11974 Datasheet HTML 1Page - Agilent(Hewlett-Packard) 11974 Datasheet HTML 2Page - Agilent(Hewlett-Packard) 11974 Datasheet HTML 3Page - Agilent(Hewlett-Packard) 11974 Datasheet HTML 4Page - Agilent(Hewlett-Packard) 11974 Datasheet HTML 5Page - Agilent(Hewlett-Packard) 11974 Datasheet HTML 6Page - Agilent(Hewlett-Packard) 11974 Datasheet HTML 7Page - Agilent(Hewlett-Packard) 11974 Datasheet HTML 8Page - Agilent(Hewlett-Packard)  
Zoom Inzoom in Zoom Outzoom out
 4 / 8 page
background image
4
Specifications
Amplitude
Third-order intercept (nominal)
(For two signals spaced less than
200 MHz apart)
11974A
≥ +13 dBm
11974Q
≥ +13 dBm
11974U
≥ +13 dBm
11974V
≥ +13 dBm
IF subharmonic response (nominal)
Intercept (2nd order; response at
f
IF/2 above input signal)
f
IF/2 = 160.7 MHz
(8566B/71000C)
f
IF/2 = 155.35 MHz
(8563A/62A/61B/60A)
11974A
≥ +45 dBm
11974Q
≥ +45 dBm
11974U
≥ +45 dBm
11974V
≥ +30 dBm
Dynamic range
Refer to Figure 3
Inputs and outputs
(all values are nominal)
RF input
Waveguide size, flange type
Size
Flange
11974A
WR-28
UG 599/U
11974Q
WR-22
UG 383/U
11974U
WR-19
UG 383/U-M
11974V
WR-15
UG 385/U
Maximum
RF input
level (CW,
peak, or
average)
+25 dBm
VSWR (at
peak of
preselector
filter)
< 3.0:1
Inputs and outputs
(all values are nominal)
LO input
Connector type
SMA (f)
Frequency range
11974A
3.3 GHz to 5 GHz
11974Q
3.3 GHz to 5 GHz
11974U
4 GHz to 6 GHz
11974V
3.5 GHz to 5.3 GHz
Maximum LO
input level
+14.5 dBm to 16 dBm
VSWR
< 2.0:1 (50 Ω)
IF output
Connector type
SMA (f)
Match
< 1.6:1 (50 Ω)
Tune + span input
Connector type
BNC (f)
Options
Option 001: Input isolator attached
and included in calibration. An input
isolator provides a specified broadband
RF input match. This is important
when the device under test requires
protection from out-of-band reflections
off the 11974’s input tracking filter.
With Option 001, the 11974 conversion
loss is calibrated with the input isolator
in place so that system amplitude
accuracy is maintained.
Specifications changes for Option 001
Amplitude
Displayed average noise level and
maximum conversion loss: Add +2 dB
to the standard specifications for A, Q,
and U bands; add +3 dB for V band.
RF input VSWR
(across full waveguide band)
11974A, Q, U
< 1.6:1
11974V
< 2.3:1
RBW
=
1
0 Hz
RF input (dBm)
Displayed
average
noise floor
Second order
IF subharmonic
distortion
Image and
multiple
response
Third order
intermod
(≤ 200 MHz
signal separation)
–70
–70
–80
–90
–100
–110
–120
–130
–60
–60
–50
–50
–40
–40
–30
–30
–20
–20
–10
0
+10
+20
Figure 3. Agilent 11974A system dynamic range



Html Pages

1 2 3 4 5 6 7 8


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com