| Electronic Components Datasheet Search |
|
AD7357 Datasheet(PDF) 18 Page - Analog Devices |
|
|
|||||||||||||||||||||||||||||
AD7357 Datasheet(HTML) 18 Page - Analog Devices |
|
18 / 20 page ![]() AD7357 Rev. 0 | Page 18 of 20 SERIAL INTERFACE Figure 30 shows the detailed timing diagram for serial inter- facing to the AD7357. The serial clock provides the conversion clock and controls the transfer of information from the AD7357 during conversion. There is a single sample delay in the result that is clocked out from the AD7357. The CS signal initiates the data transfer and conversion process. The falling edge of CS puts the track-and-hold into hold mode at which point the analog input is sampled and the bus is taken out of three-state. The conversion is also initiated at this point and requires a minimum of 16 SCLKs to complete. When 16 SCLK falling edges have elapsed, the track-and-hold goes back into track on the next SCLK rising edge, as shown in at Point B. On the rising edge of Figure 30 CS, the conversion is terminated and SDATAA and SDATAB go back into three-state. If CS is not brought high but is, instead, held low for an additional 16 SCLK cycles on SDATA , the data from the conversion on ADC B is output on SDATAA. Likewise, if CS is held low for an additional 16 SCLK cycles on SDATAA, the data from the conversion on ADC A is output on SDATAB (see ). In this case, the SDATA line in use goes back into three-state on the 32nd SCLK falling edge or the rising edge of Figure 31 CS, whichever occurs first. A minimum of 16 serial clock cycles are required to perform the conversion process and to access data from one conversion on either data line of the AD7357. Note that the data that is accessed on SDATAA and SDATAB is the result of the previous conversion. CS going low provides the leading zero to be read in by the microcontroller or DSP. The remaining data is then clocked out by subsequent SCLK falling edges, beginning with a second leading zero. Thus, the first falling clock edge on the serial clock has the leading zero provided and also clocks out the second leading zero. The 14-bit result then follows with the final bit in the data transfer valid on the 16th falling edge, having been clocked out on the previous (15th) falling edge. In applica- tions with a slower SCLK, it may be possible to read in data on each SCLK rising edge depending on the SCLK frequency. The first rising edge of SCLK after the CS falling edge has the second leading zero provided, and the 15th rising SCLK edge has DB0 provided. A CS SCLK 1 5 15 16 SDATAA SDATAB 2 LEADING ZEROS THREE- STATE t4 2 34 t5 t3 tQUIET t2 THREE-STATE DB13 DB12 DB2 DB0 0 t6 t7 t8 0 0 DB1 DB11 DB10 t9 tACQUISITION tCONVERT B Figure 30. Serial Interface Timing Diagram CS SCLK 1 5 16 SDATAA THREE- STATE t4 2 34 17 t5 t3 t2 THREE- STATE t6 t7 15 0 0 0 DB12B DB1B DB0B 0 18 32 31 DB13A 2 LEADING ZEROS DB12A DB11A DB0A DB13B 0 2 ZEROS Figure 31. Reading Data from Both ADCs on One SDATA Line with 32 SCLKs |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |