Electronic Components Datasheet Search
  English  ▼

X  

SLA707XM Datasheet(PDF) 16 Page - Sanken electric

Part # SLA707XM
Description  2-Phase Unipolar Stepper Motor Driver
PDF  20 Pages
Scroll/Zoom Zoom In 100%  Zoom Out
Manufacturer  SANKEN [Sanken electric]
Direct Link  http://www.sanken-ele.co.jp/en
Logo SANKEN - Sanken electric

SLA707XM Datasheet(HTML) 16 Page - Sanken electric

Back Button SLA707XM Datasheet HTML 12Page - Sanken electric SLA707XM Datasheet HTML 13Page - Sanken electric SLA707XM Datasheet HTML 14Page - Sanken electric SLA707XM Datasheet HTML 15Page - Sanken electric SLA707XM Datasheet HTML 16Page - Sanken electric SLA707XM Datasheet HTML 17Page - Sanken electric SLA707XM Datasheet HTML 18Page - Sanken electric SLA707XM Datasheet HTML 19Page - Sanken electric SLA707XM Datasheet HTML 20Page - Sanken electric  
Zoom Inzoom in Zoom Outzoom out
 16 / 20 page
background image
2-Phase Unipolar Stepper Motor Driver
SLA707xM Series
February, 2006
Sanken Electric Co.,Ltd.
I03-004EA-060227
Cautions and warnings
The calculation of control current
SLA707xMR control current Io (at Mode F) is calculated as follows:
S
REF
O
R
V
I
=
Setting the REF voltage more than 2V activates the sleep mode 1 (all outputs are in OFF state).
Even in this case, the internal logic circuit is alive.
Logic input/output (RESET, CLOCK, CW/CCW, M1, M2, M3, SYNC, Mo)
• The timing shown below shall comply with the "Logic input timing".
-The rising edge timing of CW/CCW, M1, M2, M3 and CLOCK input
-The RESET release timing (=the falling edge on RESET input) and the rising edge timing of CLOCK
input
*In case the above does not comply with the "Logic input timing", the device may operate with an
unexpected sequence.
• Be sure not to leave the logic inputs (RESET, CLOCK, CW/CCW, M1, M2, M3, SYNC) open.
Be sure to connect the unused logic inputs to VDD or GND.
*In case any of the logic inputs are left "OPEN", malfunction may occur due to external noises.
• When the logic output (Mo) is not used, be sure to keep it "OPEN".
*In case it is connected to VDD or GND, it may cause the device's deterioration or/and breakdown.
Mounting on a heat sink
1) Recommended Mounting Torque (on an External Heat sink)
0.490 to 0.822N•m
2) Recommended Silicone
G746
{SHIN-ETSU CHEMICAL}
YG6260
{TOSHIBA SILICONE}
SC102
{DOW CORNING TORAY SILICONE}
16/20



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com