| Electronic Components Datasheet Search |
|
MAXQ3183-RAN+ Datasheet(PDF) 59 Page - Maxim Integrated Products |
|
|
|||||||||||||||||||||||||||||
MAXQ3183-RAN+ Datasheet(HTML) 59 Page - Maxim Integrated Products |
|
59 / 102 page ![]() Low-Power, Multifunction, Polyphase AFE with Harmonics and Tamper Detect ______________________________________________________________________________________ 59 is taking place, i.e., both tasks are executed simultane- ously sharing CPU time. It is essential that the DSP postprocessing calculations be completed before the next DSP trigger to avoid losing accumulated data. The master should allow enough processing time by adjusting the R_ADCRATE register. Default settings provide plenty of CPU time for both tasks. The MAXQ3183 accumulates raw sums and calculates line-cycle integrals for each voltage-current pair sepa- rately. The individual power accumulators are: • PA = VA x IA • PB = IB x VB or -IB x VC or -IB x (VA + VC) or -IB x (VA - VC) • PC = VC x IC The PA and PC accumulators always operate in a sin- gle mode: (VA x IA) for the PA accumulator, (VC x IC) for the PC accumulator. Alternately, the operating mode of the PB accumulator is defined by setting the CON- CFG[1:0] bits in the OPMODE1 register. Energy Accumulation Start Delay All filters have a certain settling time before accurate energy readings can be accumulated. To avoid accu- mulation of invalid data from filters that are still settling, an energy accumulation timeout period can be set in the ACC_TIMO register. When ACC_TIMO > 0, comput- ed energy is not accumulated for ACC_TIMO of DSP cycles. The MAXQ3183 will decrement the ACC_TIMO register every DSP cycle until it becomes 0. When ACC_TIMO reaches 0 value, energy accumulation begins (or resumes, if ACC_TIMO was set to nonzero value by the master). Pulse outputs are also disabled when ACC_TIMO > 0. The default value of ACC_TIMO is 0x05. No-Load Feature To avoid “meter creep,” no energy accumulation should take place when measured current is less than a cer- tain threshold. The NOLOAD register can be pro- grammed to enable and configure this feature. If the measured X.IRMS value for a phase (A, B, or C) falls below the NOLOAD threshold, the energy accumulators for this phase are not incremented. Setting NOLOAD = 0 disables this feature. Full scale is represented by 0x10000. On Demand Calculations So far in this discussion, the values being calculated and managed in the MAXQ3183 have been based on fundamental units meaningful to the device itself: volt- age as a binary fraction of full-scale voltage; current as a binary fraction of full-scale current, and time as a non- integer multiple of the ADC frame time. But a practical electricity meter must report its results in standard units, such as volts, amperes, and watts. The MAXQ3183 contains a mechanism to convert the inter- nal units (“meter units”) to real world units (“display units”). This conversion is performed in the conversion constant (CC) registers. For some of these values (voltage, current) the calcula- tion is simple: multiply by the conversion constant. For other values (power, energy) the calculation is more complex. In any case, the value in the CC register affects only the conversion from a meter unit to a dis- play unit; calibration is handled separately in the gain adjustment registers for each recorded value. The results of all on-demand calculations are reported as 8-byte (64-bit) values of which no more than 6 bytes (48 bits) are significant. Eight bytes are used as a com- mon length; however, fewer bytes can be requested for those registers known to have smaller maximum values. For example, the power factor virtual register has a maximum value that is expressed in only 3 bytes; con- sequently, the register can be requested with a length of 4 bytes without loss of data. RMS Volts, RMS Amps These registers (V.A, V.B, V.C, I.A, I.B, I.C) are calculat- ed by simply multiplying the calculated RMS value (A.VRMS, B.VRMS, C.VRMS, A.IRMS, B.IRMS, C.IRMS) by the contents of the VOLT_CC or AMP_CC register. Since the RMS voltage and RMS current are given in 32-bit registers and the conversion coefficients are given in 16-bit registers, the result of the product is 48 bits. Regardless of the internal units used, VOLT_CC and AMP_CC can be tailored so that the LSB of the virtual register can be any value. For example, if one wished to have a 32-bit value representing milliamps, one could multiply by a value that scaled the register such that the LSB was 2-16mA. Then, discard the low-order 16 bits. The result is milliamps with 32 bits of precision; thus, the maximum current that could be represented would be 4,294,967,296mA, or just over 4MA. |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |