Back Button AD7298 Datasheet HTML 7Page - Analog Devices AD7298 Datasheet HTML 8Page - Analog Devices AD7298 Datasheet HTML 9Page - Analog Devices AD7298 Datasheet HTML 10Page - Analog Devices AD7298 Datasheet HTML 11Page - Analog Devices AD7298 Datasheet HTML 12Page - Analog Devices AD7298 Datasheet HTML 13Page - Analog Devices AD7298 Datasheet HTML 14Page - Analog Devices AD7298 Datasheet HTML 15Page - Analog Devices Next Button
Zoom Inzoom in Zoom Outzoom out
 11 / 18 page
background image
Preliminary Technical Data
AD7298
Rev. PrA | Page 11 of 18
POWER-DOWN MODES
The AD7298 has a number of power conservation modes of
operation, which are designed to provide flexible power
management options. These options can be chosen to optimize
the power dissipation/throughput rate ratio for different
application requirements. The power-down modes of operation
of the AD7298 is controlled by the power-down bit, in the
control register and the PD pin on the device. When power
supplies are first applied to the AD7298, care should be taken to
ensure that the part is placed in the required mode of operation
NORMAL MODE
This mode is intended for the fastest throughput rate perform-
ance because the user does not have to worry about any power-
up times with the AD7298 remaining fully powered at all times.
Figure 6 shows the general diagram of the operation of the
AD7298 in this mode. The conversion is initiated on the falling
edge of CS and the track-and-hold enters hold mode. On the14th
SCLK falling edge the track-and-hold returns to track mode
and starts acquiring the analog input, as described in the serial
interface section. The data presented to the AD7298 on the DIN
line during the first 16 clock cycles of the data transfer are
loaded into the control register (provided the WRITE bit is 1).
The part remains fully powered up in normal mode at the end
of the conversion as long as PD bit is set to 0 in the write transfer
during that conversion. To ensure continued operation in
normal mode, the PD bit should be loaded with 0 on every data
write operation. Sixteen serial clock cycles are required to
complete the conversion and access the conversion result.
For specified performance, the throughput rate should not
exceed 1MSPS. Once a conversion is complete and the CS has
returned high, a minimum of the quiet time, tQUIET, must elapse
before bringing CS low again to initiate another conversion and
access the previous conversion result.
Figure 6. Normal Mode Operation
PARTIAL POWER DOWN MODE
In this mode, part of the internal circuitry on the AD7298 is
powered-down. The AD7298 enters partial power-down on the
CS rising edge once the current serial write operation
containing 16 SCLK clock cycles is completed. To enter partial
power-down the PD bit in the control register should be set to
one on the last required read transfer from the AD7298. Once
in partial power-down mode the AD7298 transmits all ones on
the DOUTpin if
The AD7298 remains in partial power-down until the power-
down bit, PD, in the control register is changed to a logic level
zero (0). The AD7298 begins powering up on the rising edge of
CS is toggled low. If the averaging feature for the
temperature sensor is enabled in the control register, the
averaging is reset once the device enters partial power-down
mode.
CS following the write to the control register disabling the
power-down bit. Once TQUITE has elapsed, a full 16-SCLK write
to the control register must be completed to update its content
with the desired channel configuration for the subsequent
conversion. A valid conversion is then initiated on the next
Figure 7
CS
falling edge. Since the AD7298 has once cycle latency, the first
conversion result after exiting partial power-down mode is
available in the fourth serial transfer as shown in
; 1st
cycle to update PD bit, 2nd cycle to update configuration and
Channel ID bits, 3rd to complete conversion, 4th access DOUT
valid result. The use of this mode enables a reduction in the
overall power consumption of the device.



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com