Electronic Components Datasheet Search
  English  ▼

X  

34832A Datasheet(PDF) 4 Page - Agilent(Hewlett-Packard)

Part # 34832A
Description  BenchLink Data Logger Pro
PDF  4 Pages
Scroll/Zoom Zoom In 100%  Zoom Out
Manufacturer  HP [Agilent(Hewlett-Packard)]
Direct Link  http://www.home.agilent.com
Logo HP - Agilent(Hewlett-Packard)

34832A Datasheet(HTML) 4 Page - Agilent(Hewlett-Packard)

  34832A Datasheet HTML 1Page - Agilent(Hewlett-Packard) 34832A Datasheet HTML 2Page - Agilent(Hewlett-Packard) 34832A Datasheet HTML 3Page - Agilent(Hewlett-Packard) 34832A Datasheet HTML 4Page - Agilent(Hewlett-Packard)  
Zoom Inzoom in Zoom Outzoom out
 4 / 4 page
background image
For more information on repair and
calibration services, go to
www.agilent.com/find/removealldoubt
Agilent Email Updates
www.agilent.com/find/emailupdates
Get the latest information on the products
and applications you select.
Agilent Direct
www.agilent.com/find/agilentdirect
Quickly choose and use your test
equipment solutions with confidence.
www.agilent.com
For more information on Agilent Technologies’
products, applications or services, please contact
your local Agilent office. The complete list is
available at:
www.agilent.com/find/contactus
Americas
Canada
(877) 894-4414
Latin America
305 269 7500
United States
(800) 829-4444
Asia Pacific
Australia
1 800 629 485
China
800 810 0189
Hong Kong
800 938 693
India
1 800 112 929
Japan
0120 (421) 345
Korea
080 769 0800
Malaysia
1 800 888 848
Singapore
1 800 375 8100
Taiwan
0800 047 866
Thailand
1 800 226 008
Europe & Middle East
Austria
01 36027 71571
Belgium
32 (0) 2 404 93 40
Denmark
45 70 13 15 15
Finland
358 (0) 10 855 2100
France
0825 010 700*
*0.125 €/minute
Germany
07031 464 6333
Ireland
1890 924 204
Israel
972-3-9288-504/544
Italy
39 02 92 60 8484
Netherlands
31 (0) 20 547 2111
Spain
34 (91) 631 3300
Sweden
0200-88 22 55
Switzerland
0800 80 53 53
United Kingdom 44 (0) 118 9276201
Other European Countries:
www.agilent.com/find/contactus
Revised: March 24, 2009
Microsoft, Windows, and Windows NT are U.S.
registered trademarks of Microsoft Corporation.
Adobe and Acrobat are trademarks of Adobe
Systems Incorporated.
Pentium is a U.S. registered trademark of Intel
Corporation.
Product specifications and descriptions
in this document subject to change
without notice.
© Agilent Technologies, Inc. 2007
Printed in USA, June 16, 2009
5989-7621EN
Specifications
System requirements
Operating system:
Windows Vista, XP SP2, 2000 SP4 (does
not support any home editions)
Controller: Recommend Pentium® 4,
800 MHz or greater, min. Pentium III,
500 MHz
RAM: Recommend 256 MB or greater,
min. 128 MB
Disk space: Recommend 200 MB,
min. 100 MB
Display: 1024 x 768 resolution, 256 colors
Adobe® Acrobat® Reader V5.0 or higher
(to view documentation)
Included run-time software
components
• Microsoft .NET V2.0
• Microsoft Data access components
V2.8 SP1
• Microsoft Internet Explorer V6.0
• Agilent IO Libraries Version 14.1 or later
(included on a separate CD)
Supported instruments
34980A Multifunction switch/measure
unit with DMM and any of the following
modules:
• 34921A/22A/23A/24A/25A Multiplexers
• 34931A/32A/33A Matrix switches
• 34937A/38A GP Switches
• 34941A/42A/46A/47A High frequency
switches
• 34952A Multifunction module
• Supports one instrument at full speed
or 2 instruments at a reduced speed
If you have a 34830A license as well, then
you can configure up to two 34970As and
one 34980A into a single configuration.
Supported interfaces
• IEEE-488 GPIB, LAN, USB (at 9600 baud
rate)
Performance
Scanning speeds with 34980A*:
343921A/22A 100 ch/sec
34923A/24A 500 ch/sec
34925A 900 ch/sec
34952A DIO read/write speed 95 ch/sec
* Speeds are for 4½ digits, delay 0, display off,
autozero off. Scanning is within bank on the
same module. Add 10 ms for between banks
or modules. See the 34980A data sheet for
additional 34980A performance specs
Localization
GUI fully localized with context-sensitive
help in English, Simplified Chinese,
Japanese, Korean, French, and German.
Ordering and licensing information
The BenchLink Data Logger software
ships for free with every 34980A that has
the internal DMM. The BenchLink Data
Logger Pro software can be found on the
same CD-ROM and can be used for 30
days with no obligation. After 30 days a
software license is required to continue
to use this software. Each PC requires a
separate license. Go to www.agilent.com/
find/34832A for purchasing information.
Related literature
Agilent 34980A Multifunction Switch/
Measure Unit, Data Sheet 5989-1437EN



Html Pages

1 2 3 4


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com