Back Button AS8118 Datasheet HTML 11Page - ams AG AS8118 Datasheet HTML 12Page - ams AG AS8118 Datasheet HTML 13Page - ams AG AS8118 Datasheet HTML 14Page - ams AG AS8118 Datasheet HTML 15Page - ams AG AS8118 Datasheet HTML 16Page - ams AG AS8118 Datasheet HTML 17Page - ams AG AS8118 Datasheet HTML 18Page - ams AG AS8118 Datasheet HTML 19Page - ams AG Next Button
Zoom Inzoom in Zoom Outzoom out
 15 / 30 page
background image
Data Sheet AS8118
Revision 1.8, 15-Feb-05
Page 15 of 30
Defined Current and Calibration Time Method
The AS8118 generates a pulse whenever the internal energy accumulator contains a value, which is greater than a
programmed threshold. This threshold is the parameter Pulse_lev. This parameter depends on the basic meter properties,
the mains voltage Vmains and the maximum current to be measured, Imax. Furthermore, it is assumed that through a resistor
divider Vmains is scaled down to match the maximum input range of the VP input.
Firstly, an ideal value for Pulse_lev is calculated. This is the value, which would have to be programmed into the AS8118
device if the meter system was perfect.
The following formula calculates this ideal value of Pulse_lev:
435924
20
230
*
I
A
*
V
V
)
ideal
(
lev
_
Pulse
max
mains
=
A calibration is performed to compensate for system non-idealities like resistor tolerances etc. The effect of these non-
idealities is that with the ideal Pulse_lev value the pulse rates will not be correct. In order to calibrate the meter, a new
Pulse_lev
value has to be found. Figure 6 shows the basic calibration setup. CAL pulses from a meter built with the AS8118
are counted during a defined time period tc, while an accurately defined calibration current Ical, is being measured.
Calboard
AS8118
Meter
I
cal
time
base
t
c
Figure 6
Basic calibration setup for defined current and calibration time method
Again, if the system was perfect we would expect a certain number of pulses to be counted, the ideal number of pulses, Ni:
1000
3600 *
Ical
*
V
*
tc
*
PR
Ni
mains
=
where tc is in seconds.
PR is the pulse rate on pin CAL, which can be calculated from the PROM parameters F_mon_sel and F_cal_sel:
Fcal
*
Fmon
PR
=
where Fmon [imp/kWh] is the pulse rate selected by F_mon_sel and Fcal is the multiplier selected by F_cal_sel.
If pin LED is used for calibration then PR is the pulse rate on pin LED (selected by F_led_sel).
The corrected value for Pulse_lev can now be calculated using the following formula:
Ni
Nr
*
)
ideal
(
lev
_
Pulse
)
corrected
(
lev
_
Pulse
=
,
where Nr is the real number of pulses, i.e. the number of pulses counted during tc.



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com