Back Button MAX17040 Datasheet HTML 5Page - Maxim Integrated Products MAX17040 Datasheet HTML 6Page - Maxim Integrated Products MAX17040 Datasheet HTML 7Page - Maxim Integrated Products MAX17040 Datasheet HTML 8Page - Maxim Integrated Products MAX17040 Datasheet HTML 9Page - Maxim Integrated Products MAX17040 Datasheet HTML 10Page - Maxim Integrated Products MAX17040 Datasheet HTML 11Page - Maxim Integrated Products MAX17040 Datasheet HTML 12Page - Maxim Integrated Products MAX17040 Datasheet HTML 13Page - Maxim Integrated Products  
Zoom Inzoom in Zoom Outzoom out
 11 / 13 page
background image
Basic Transaction Formats
A write transaction transfers 2 or more data bytes to the
MAX17040/MAX17041. The data transfer begins at the
memory address supplied in the MAddr byte. Control of
the SDA signal is retained by the master throughout the
transaction, except for the acknowledge cycles:
A read transaction transfers 2 or more bytes from the
MAX17040/MAX17041. Read transactions are com-
posed of two parts, a write portion followed by a read
portion, and are therefore inherently longer than a write
transaction. The write portion communicates the starting
point for the read operation. The read portion follows
immediately, beginning with a Repeated START, Slave
Address with R/W set to a 1. Control of SDA is assumed
by the MAX17040/MAX17041, beginning with the Slave
Address Acknowledge cycle. Control of the SDA signal
is retained by the MAX17040/MAX17041 throughout the
transaction, except for the acknowledge cycles. The
master indicates the end of a read transaction by
responding to the last byte it requires with a no
acknowledge. This signals the MAX17040/MAX17041
that control of SDA is to remain with the master following
the acknowledge clock.
Write Data Protocol
The write data protocol is used to write to register to the
MAX17040/MAX17041 starting at memory address
MAddr. Data0 represents the data written to MAddr,
Data1 represents the data written to MAddr + 1, and
DataN represents the last data byte, written to MAddr +
N. The master indicates the end of a write transaction
by sending a STOP or Repeated START after receiving
the last Acknowledge bit:
The MSB of the data to be stored at address MAddr
can be written immediately after the MAddr byte is
acknowledged. Because the address is automatically
incremented after the LSB of each byte is received by
the MAX17040/MAX17041, the MSB of the data at
address MAddr + 1 can be written immediately after
the acknowledgment of the data at address MAddr. If
the bus master continues an autoincremented write
transaction beyond address 4Fh, the MAX17040/
MAX17041 ignore the data. A valid write must include
both register bytes. Data is also ignored on writes to
read-only addresses. Incomplete bytes and bytes that
are not acknowledged by the MAX17040/MAX17041
are not written to memory.
Read Data Protocol
The read data protocol is used to read to register from
the MAX17040/MAX17041 starting at the memory
address specified by MAddr. Both register bytes must
be read in the same transaction for the register data to
be valid. Data0 represents the data byte in memory
location MAddr, Data1 represents the data from MAddr
+ 1, and DataN represents the last byte read by the
master:
Data is returned beginning with the MSB of the data in
MAddr. Because the address is automatically incre-
mented after the LSB of each byte is returned, the MSB
of the data at address MAddr + 1 is available to the
host immediately after the acknowledgment of the data
at address MAddr. If the bus master continues to read
beyond address FFh, the MAX17040/MAX17041 output
data values of FFh. Addresses labeled Reserved in the
memory map return undefined data. The bus master
terminates the read transaction at any byte boundary
by issuing a no acknowledge followed by a STOP or
Repeated START.
S. SAddr W. A. MAddr. A. Sr. SAddr R. A.
Data0. A. Data1. A... DataN. N. P
SAddr W. A. MAddr. A. Data0. A. Data1. A... DataN. A
Read: S. SAddr W. A. MAddr. A. Sr. SAddr R. A. Data0. A. Data1. N. P
Write Portion
Read Portion
Write: S. SAddr W. A. MAddr. A. Data0. A. Data1. A. P
Compact, Low-Cost 1S/2S Fuel Gauges
______________________________________________________________________________________
11
KEY
DESCRIPTION
KEY
DESCRIPTION
S
START bit
Sr
Repeated START
SAddr
Slave address (7 bit)
W
R/W bit = 0
MAddr
Memory address byte
P
STOP bit
Data
Data byte written by master
Data
Data byte returned by slave
A
Acknowledge bit—master
A
Acknowledge bit—slave
N
No acknowledge—master
N
No acknowledge—slave
Table 5. 2-Wire Protocol Key



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com