7 / 8 page ![]() HLS30 Series – 30A Half-Brick DC/DC Converter 48V Input Data Sheet 5.0V, 3.3V, 2.5V Output Rev. 10/01 Page 7 of 8 value of the fuse without opening. The fuse must not be placed in the grounded input line, if any. In order for the output of the HLS30 series converter to be considered as SELV (Safety Extra Low Voltage) or TNV-1, according to all IEC60950 based standards, one of the following requirements must be met in the system design: • If the voltage source feeding the module is SELV or TNV-2, the output of the converter may be grounded or ungrounded. • If the voltage source feeding the module is ELV, the output of the converter may be considered SELV only if the output is grounded per the requirements of the standard. • If the voltage source feeding the module is a Hazardous Voltage Secondary Circuit, the voltage source feeding the module must be provided with at least Basic insulation between the source to the converter and any hazardous voltages. The entire system, including the HLS30 converter, must pass a dielectric withstand test for Reinforced insulation. Design of this type of systems requires expert engineering and understanding of the overall safety requirements and should be performed by qualified personnel. Thermal Considerations The HLS30 series converters are designed for natural or forced convection cooling. The maximum allowable output power of the converters is determined by meeting the derating criteria of all electronic components used in the power supplies. An example of the derating criteria for the semiconductor junction temperature is not to exceed 120C to provide reliable long-term operation of the converters. Note: Please contact Power-One for more derating criteria for other components. The graphs in Figures 10-12 show the maximum output current of the HLS30 series converters at different ambient temperatures under both natural and forced (longitudinal airflow direction, from pin 1 to pin 4) convection. As an example, from Figure 10, the HLS30ZG operating at 55C can deliver up to 25.5A reliably with 100LFM forced air, while up to 28A reliably with 200LFM forced air. Fig.10 HLS30ZG (5V) derating curves Fig.11 HLS30ZE (3.3V) derating curves Fig.12 HLS30ZD (2.5V) derating curves . |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |