| Electronic Components Datasheet Search |
|
MAP30 Datasheet(PDF) 2 Page - Power-One |
|
|
|||||||||||||||||||||||||||||
MAP30 Datasheet(HTML) 2 Page - Power-One |
|
2 / 4 page ![]() 2 INPUT SPECIFICATIONS PARAMETER CONDITIONS/DESCRIPTION MIN NOM MAX UNITS Input Voltage - AC Continuous input range. MAP42 85 264 VAC MAP30, MAP40 90 264 Input Frequency AC input. 47 63 Hz Brown Out Protection Lowest AC input voltage that regulation is maintained with full rated loads. 85 VAC Hold-up Time Nominal AC Input Voltage (115VAC), full rated load. 15 mS Input Current 90 VAC (40W load). 1.2 ARMS Input Protection Non-user serviceable internally located AC input line fuse. Inrush Surge Current Internally limited by thermistor. Vin = 264VAC (one cycle). 25° C. 38 APK Operating Frequency Switching frequency of power supply (fixed frequency). 23 25 30 kHz OUTPUT SPECIFICATIONS PARAMETER CONDITIONS/DESCRIPTION MIN NOM MAX UNITS Efficiency Full load, 120VAC. 70 % Minimum Loads Single output models; MAP30, MAP42. 0.0 Amps All multiple output models, see regulation graphs. Ripple and Noise Full load, 20MHz bandwidth. See Model Selection Chart. Output Power Multiple output models with convection cooling. 40 Watts Overshoot / Undershoot Output voltage overshoot/undershoot at turn-on, V1. 1 % Regulation Varies by output, total regulation includes: Line changes from 90-132 VAC or 175-264, changes in load starting at 20% load and changing See regulation graphs. to 100% load. Transient Response Recovery time, to within 1% of initial set point due to a 50-100% 500 µS load change, 4% max. deviation. (Main output only of multiple output units). Turn-on Delay Time required for initial output voltage stabilization. 1 2 Sec Turn-on Rise Time Time required for output voltage to rise from 10% to 90%. 20 mS INTERFACE SIGNALS AND INTERNAL PROTECTION PARAMETER CONDITIONS/DESCRIPTION MIN NOM MAX UNITS MAP30-1005, MAP42-1005 5.8 6.8 Overvoltage MAP42-1012 20.0 22.0 V Protection MAP42-1024 32.0 37.0 Main output only of multiple output units. 5.8 6.8 Overload Fully protected against output overload and short circuit. Automatic 130 % Protection recovery upon removal of overload condition. Remote Sense Total cable drop, single output models only. 250 mV SAFETY, REGULATORY, AND EMI SPECIFICATIONS PARAMETER CONDITIONS/DESCRIPTION MIN NOM MAX UNITS Agency Approvals UL1950. CSA 22.2 No. 234/950. Approved. EN60950 (TUV). Dielectric Withstand Input to output. 2600 VDC Voltage Electromagnetic FCC CFR title 47 part 15 sub-part B - conducted. B Interference EN55022 / CISPR 22 conducted (Note 1). B Class EN55022 / CISPR 22 radiated (Note 2). B Input Transient EN61000-4-5 Level 3 Line to Line 1 kV Protection Line to Ground 2 Insulation Resistance Input to output. 7 M Ω Leakage Current Per EN60950, 264VAC MAP42, MAP40-3100, 3001, 3105, 3500 500 µA MAP30-1005, MAP40-3000, MAP40-3003 750 NOTES: 1) MAP30-1005, MAP40-3000, MAP40-3003 meet Class A. 2) MAP40-3000, MAP40-3003, MAP3500 meet Class A. MAP30/40/42 SERIES |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |