82 / 170 page ![]() GENERAL RELEASE SPECIFICATION August 27, 1998 MOTOROLA SM-BUS MC68HC05SB7 12-4 REV 2.1 Each data byte is 8 bits long. Data can be changed only when SCL is low and must be held stable when SCL high as shown in Figure 12-2. The MSB is trans- mitted first and each byte has to be followed by an acknowledge bit. This is sig- nalled by the receiving device by pulling the SDA low on the 9th clock cycle. Therefore one complete data byte transfer needs 9 clock cycles. If the slave receiver does not acknowledge the master, the SDA line should be left high by the slave. The master can then generate a STOP signal to abort the data transfer or a START signal (repeated start) to commence a new transfer. If the master receiver does not acknowledge the slave transmitter after a byte has been transmitted, it means an “end of data” to the slave. The slave should now release the SDA line for the master to generate a “STOP” or “START” signal. 12.4.4 Repeated START Signal As shown in Figure 12-2, a repeated START signal is used to generate a START signal without first generating a STOP signal to terminate the communication. This is used by the master to communicate with another slave or with the same slave in a different mode (transmit/receive mode) without releasing the bus. 12.4.5 STOP Signal With reference to Figure 12-2, the master can terminate the communication by generating a STOP signal to free the bus. However, the master may generate a START signal followed by a calling command without first generating a STOP sig- nal. This is called repeat start. A STOP signal is defined as a low to high transition of SDA while SCL is at logical high. 12.4.6 Arbitration Procedure This interface circuit is a true multi-master system which allows more than one master to be connected to it. If two or more masters try to control the bus at the same time, a clock synchronization procedure determines the bus clock, for which the low period is equal to the longest clock low period and the high is equal to the shortest one among the masters. A data arbitration procedure determines the pri- ority. The masters will lose arbitration if they transmit logic “1” while another trans- mits logic “0”. The losing masters will immediately switch over to slave receive mode and stop its data and clock outputs. The transition from master to slave mode will not generate a STOP condition in this case. Meanwhile a software bit will be set by hardware to indicate loss of arbitration. |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |