| Electronic Components Datasheet Search |
|
AMR2815S/EM Datasheet(PDF) 4 Page - International Rectifier |
|
|
|||||||||||||||||||||||||||||
AMR2815S/EM Datasheet(HTML) 4 Page - International Rectifier |
|
4 / 7 page ![]() 4 www.irf.com AMR28XXS Series Dynamic Characteristics -55°C ≤ TCASE ≤ +125°C, VIN=28 VDC ±5%, C L=0, unless otherwise specified. Parameter Group A Subgroups Test Conditions Min Nom Max Unit Output Response To Step Transient Load Changes 7 AMR2803R3S AMR2805S AMR2812S AMR2815S AMR2803R3S AMR2805S AMR2812S AMR2815S 4, 5, 6 4, 5, 6 4, 5, 6 4, 5, 6 4, 5, 6 4, 5, 6 Load step 50% Ù 100% Load step 8% Ù 50% -500 -500 -800 -1000 -500 -500 -1000 -1000 +500 +500 +800 +1000 +500 +500 +1000 +1000 mVpk Recovery Time, Step Transient Load Changes 7, 8 4, 5, 6 Load step 50% Ù 100% or Load step 8% Ù 50% 200 µs Output Response Transient Step Line Changes 5, 9 AMR2803R3S AMR2805S AMR2812S AMR2815S 4, 5, 6 4, 5, 6 4, 5, 6 4, 5, 6 Input step from/to 18 to 40Vdc, 100% load -500 -500 -1200 -1500 +500 +500 +1200 +1500 mVpk Recovery Time Transient Step Line Changes 5, 8, 9 4, 5, 6 Input step from/to 18 to 40Vdc, 100% load 10 ms Turn On Overshoot AMR2803R3S AMR2805S AMR2812S AMR2815S 4, 5, 6 4, 5, 6 4, 5, 6 4, 5, 6 0% load to 100% load 500 500 800 1000 mVpk Turn On Delay 10 4, 5, 6 0% load to 100% load 25 ms Short Circuit Recovery 5, 10 4, 5, 6 25 ms 1 Parameter guaranteed by line and load regulation tests. 2 Bandwidth guaranteed by design. Tested for 20 KHz to 2.0 MHz. 3 Output voltage measured at load with remote sense leads connected across load. 4 Capacitive load may be any value from 0 to the maximum limit without compromising dc performance. A capacitive load in excess of the maximum limit will not disturb loop stability but may interfere with the operation of the load fault detection circuitry, appearing as a short circuit during turn on. 5 Parameter shall be tested as part of design characterization and after design or process changes. Parameters shall be guaranteed to the limit specified in Electrical Specifications. 6 Load step transition time between 2.0 and 10 microseconds. 7 Recovery time is measured from the initiation of the transient to where V OUT has returned to within ±1 % of VOUT at 50 percent load. 8 Input step transition time between 2.0 and 10 microseconds. 9 Turn on delay time measurement is for either a step application of power at the input or the removal of a ground signal from the inhibit pin while power is applied to the input. Notes to Specifications |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |