Back Button ISL97635A Datasheet HTML 8Page - Intersil Corporation ISL97635A Datasheet HTML 9Page - Intersil Corporation ISL97635A Datasheet HTML 10Page - Intersil Corporation ISL97635A Datasheet HTML 11Page - Intersil Corporation ISL97635A Datasheet HTML 12Page - Intersil Corporation ISL97635A Datasheet HTML 13Page - Intersil Corporation ISL97635A Datasheet HTML 14Page - Intersil Corporation ISL97635A Datasheet HTML 15Page - Intersil Corporation ISL97635A Datasheet HTML 16Page - Intersil Corporation Next Button
Zoom Inzoom in Zoom Outzoom out
 12 / 28 page
background image
12
FN6564.2
December 22, 2008
BRTDC can be programmed from 0 to 255 in decimal and
defaults to 255 (0xFF). If left at the default value, LED
current will be fixed at ILEDmax. BRTDC can be adjusted
dynamically on the fly during operation. BRTDC = 0
disconnects all channels and ILED is guaranteed to be
<10µA at this state.
For example, if the maximum required LED current (ILEDmax)
is 20mA, rearranging Equation 1 yields Equation 3:
If BRTDC is set to 200, then:
PWM CONTROL
The ISL97635A provides four different PWM dimming
methods, as described in the following. Each of these
methods results in PWM chopping of the current in the LEDs
for all 6 channels to provide an average LED current. During
the on-periods, the LED current will be defined by the value
of RSET and BRTDC, as described in Equations 1 and 2. The
source of the PWM signal can be described as follows:
1. Internally generated 256 step duty cycle programmed
through the SMBus.
2. External signal from PWMI.
3. DPST mode. Internally generated signal with a duty cycle
defined by the product of the external PWMI and SMBus
programmed PWM at the internal setting frequency.
4. DC-to-PWM control.
The default PWM dimming is in DPST mode. In all four
methods, the average LED current of each channel is
controlled by ILED and the PWM duty cycle in percent as
shown in Equation 5:
Method 1 (Internal Mode, SMBus controlled PWM)
The average LED current of each channel is controlled by the
internally generated PWM signal as shown in Equation 6:
where BRT is the PWM brightness level programmed in the
register 0x00. BRT ranges from 0 to 255 in decimal and
defaults to 255 (0xFF). BRT = 0 disconnects all channels
and ILED is guaranteed to be <10µA in this state.
To use only the SMBus controlled PWM brightness control,
users need to set Register 0x01 to 0x05 with EN/PWMI in
logic high.
The SMBus controlled PWM frequency is adjusted by a
capacitor at the FPWM pin, which will be described in “PWM
Dimming Frequency Adjustment” on page 13.
Method 2 (External Mode)
The average LED current of each channel can also be
controlled by an external PWMI signal, as shown in Equation 7:
The PWM dimming frequency can be for example 20kHz but
there are a minimum on and off time requirements such that
the dimming will be in the range of 10% to 99.5%. If the
dimming frequency is below 5kHz, the dimming range can
be 1% to 99.5%.
The PWM dimming off time cannot be longer than 28ms or
else the driver will enter shutdown.
To use PWMI only brightness control, users need to set
Register 0x01 to 0x03.
Method 3 (DPST Mode)
The average LED current of each channel can also be
controlled by the product of the SMBus controlled PWM and
the external PWMI signals as follows:
Where:
Therefore:
Where BRT is the value held in register 0x00 (default setting
0xFF) controlled by SMBus and PWMI is the duty cycle of
the incoming PWMI signal. In this way, the users can change
the PWM current in ratiometric manner to achieve DPST
compliance backlight dimming.
To use the DPST mode, users need to set register 0x01 to
0x01 with the external PWM signal.
The DPST mode PWM frequency is adjusted by a capacitor
at the FPWM pin. Also, a CPWMO capacitor is also needed,
which will be described in “PWM Dimming Frequency
Adjustment” on page 13.
For example, if the SMBus controlled PWM duty is 80%
dimming at 200Hz (see CFPWM in Equation 10) and the
external PWMI duty cycle is 60% dimming at 1kHz, the
resultant PWM duty cycle is 48% dimming at 200Hz.
Method 4 (Analog Mode, DC-to-PWM Mode)
By overdriving the PWMO pin with a DC voltage between
0.21V and 1.21V, the average LED current of each channel
R
SET
733 0.02
⁄
36.6k
Ω
==
(EQ. 3)
I
LED
2.87∗200 36600
⁄
15.7mA
==
(EQ. 4)
I
LED ave
()
I
LED
PWM
×
=
(EQ. 5)
I
LED ave
()
I
LED
BRT 255
⁄
()
×
=
(EQ. 6)
I
LED ave
()
I
LED
PWMI
×
=
(EQ. 7)
I
LED ave
()
I
LEDxPWMDPST
=
(EQ. 8)
PWM
DPST
BRT 255
⁄
PWMI
×
=
(EQ. 9)
I
LED ave
()
I
LED
BRT 255
⁄
×
PWMI
×
=
(EQ. 10)
ISL97635A



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com