| Electronic Components Datasheet Search |
|
NISCXI-1195 Datasheet(PDF) 2 Page - National Instruments Corporation |
|
|
|||||||||||||||||||||||||||||
NISCXI-1195 Datasheet(HTML) 2 Page - National Instruments Corporation |
|
2 / 3 page ![]() 2 BUY ONLINE at ni.com or CALL (800) 813 3693 (U.S.) Specifications All specifications are subject to change without notice. Visit ni.com/manuals for the most current specifications. Configuration PXI-2595 .............................................. 4x1 multiplexer SCXI-1195............................................ Quad 4x1 multiplexer Input Characteristics All input characteristics are DC, ACrms, or a combination unless otherwise specified. Maximum switching voltage .............. 30 V Maximum switching current............... 0.5 A Maximum carry current....................... 0.5 A Maximum RF power............................ 10 W Note: When operating the SCXI-1195 at ambient temperatures >30 °C, a load derating may apply to the total power that the module can handle. DC path resistance Initial ............................................... <0.25 Ω End of life ....................................... 1.0 Ω RF Performance Characteristics Values in parentheses are typical. Characteristic impedance (Z0)............. 50 Ω, nominal Insertion loss 1 GHz............................................... <0.7 dB (<0.4 dB) 3 GHz............................................... <1.7 dB (<1.0 dB) 5 GHz............................................... <2.8 dB (<2.0 dB) Voltage Standing-Wave Ratio (VSWR) 1 GHz............................................... <1.25 (<1.1) 3 GHz............................................... <1.50 (<1.3) 5 GHz............................................... <1.85 (<1.5) Isolation 1 GHz............................................... >70 dB (>78 dB) 3 GHz............................................... >55 dB (>69 dB) 5 GHz............................................... >30 dB (>38 dB) Typical bank-to-bank crosstalk (SCXI-1195 only) 3 GHz............................................... <-90 dB 5 GHz............................................... <-60 dB Dynamic Characteristics Maximum scan rate ............................ 45 channels/s Maximum relay operate time ............. 10.4 ms Expected relay life Mechanical ..................................... 106 cycles Electrical ......................................... 3 x 105 cycles (30 V, 10 mA, DC resistive) Physical Characteristics Relay type ........................................... electromechanical, latching I/O connectors PXI-2595.......................................... 5 SMA jacks SCXI-1195 ....................................... 20 SMA jacks Dimensions (W by H by D) PXI-2595.......................................... 3U, one slot, PXI/cPCI module 2.0 by 13.0 by 21.6 cm (0.8 by 5.1 by 8.5 in.) SCXI-1195 ....................................... 3.0 by 17.3 by 19.8 cm (1.2 by 6.8 by 7.8 in.) Environment Operating temperature ....................... 0 to 55 °C (0 to 50 °C for SCXI) Storage temperature........................... -20 to 70 °C Relative humidity ................................ 5 to 85% noncondensing Pollution degree .................................. 2 Approved at altitudes up to 2,000 m. Indoor use only. Compliance and Certifications Safety This product meets the requirements of the following standards of safety for electrical equipment for measurement, control, and laboratory use: • IEC 61010-1, EN 61010-1 • UL 61010-1 • CAN/CSA-C22.2 No. 61010-1 Note: For UL and other safety certifications, refer to the product label, or visit ni.com/certification, search by model number or product line, and click the appropriate link in the Certification column. Electromagnetic Compatibility Emissions ............................................ EN 55011 Class A at 10 m FCC Part 15A above 1 GHz Immunity.............................................. EN 61326:1997 +A2:2001, Table 1 EMC/EMI............................................. CE, C-Tick, and FCC Part 15 (Class A) Compliant CE Compliance This product meets the essential requirements of applicable European Directives, as amended for CE marking, as follows: Low-Voltage Directive (safety) ........... 73/23/EEC Electromagnetic Compatibility Directive (EMC) ................................... 89/336/EEC Note: Refer to the Declaration of Conformity (DoC) for this product for any additional regulatory compliance information. To obtain the DoC for this product, visit ni.com/certification, search by model number or product line, and click the appropriate link in the Certification column. |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |