| Electronic Components Datasheet Search |
|
MOR283R3S Datasheet(PDF) 12 Page - Interpoint Corporation Company |
|
|
|||||||||||||||||||||||||||||
MOR283R3S Datasheet(HTML) 12 Page - Interpoint Corporation Company |
|
12 / 24 page ![]() Electrical Characteristics: -55°C to +125°C TC, 28 VDC Vin, 100% load, free run, unless otherwise specified. DUAL OUTPUT MODELS MOR289R5D MOR2812D MOR2815D unitS Parameter ConditionS MIN TYP MAX MIN TYP MAX MIN TYP MAX outPut Voltage 2 +Vout 9.31 9.50 9.69 11.76 12.00 12.24 14.70 15.00 15.30 VDC -Vout 9.26 9.50 9.74 11.70 12.00 12.30 14.62 15.00 15.38 outPut Current 3 eaCh outPut — ±5.53 7.75 1 — ±4.58 6.4 1 — ±4.00 5.6 1 A Vin = 16 to 40 VdC total — — 11.05 — — 9.16 — — 8 outPut Power 3 eaCh outPut — ±52.5 73.5 1 — ±55 77 1 — ±60 84 1 W Vin = 16 to 40 VdC total — — 105 — — 110 — — 120 outPut riPPle ±Vout 10 khz - 20 mhz — 75 120 — 75 120 — 75 150 mV p-p 10 khz - 2 mhz — 50 80 — 50 100 — 50 120 line regulation Vin = 16 to 40 VdC +Vout — 25 50 — 25 50 — 25 50 mV -Vout — 50 100 — 50 100 — 50 100 load regulation +Vout — 25 50 — 25 50 — 25 50 mV -Vout — 50 200 — 50 200 — 50 200 CroSS regulation 1, 4 -Vout — 4 7 — 3 5 — 2 4 % inPut Voltage ContinuouS 16 28 40 16 28 40 16 28 40 VDC TRANSIENT 120 ms 1 — — 50 — — 50 — — 50 V inPut Current no load — 70 160 — 70 160 — 70 160 inhibited–inh1 — — 10 — — 10 — — 10 mA inhibited–inh2 — — 70 — — 70 — — 70 inPut riPPle Current 10 mhz - 20 mhz — — 130 — — 130 — — 130 mA p-p eFFiCienCy 80 84 — 82 86 — 83 87 — % load Fault Power diSSiPation oVerload 1 — — 30 — — 30 — — 30 W Short CirCuit 5 — — 24 — — 22 — — 20 reCoVery 1 — — 10 — — 10 — — 10 ms SteP load reSPonSe ±Vout 50% - 100% - 50% tranSient — — 500 — — 600 — — 600 mV pk reCoVery 6 — — 300 — — 300 — — 300 µs SteP line reSPonSe ±Vout 16 - 40 - 16 VdC tranSient 1, 7 — — 600 — — 600 — — 750 mV pk reCoVery 1, 6 — — 300 — — 300 — — 300 µs Start-uP 8 delay — — 10 — — 10 — — 10 ms oVerShoot 1 — — 50 — — 25 — — 50 mV pk CaPaCitiVe load 1 no eFFeCt on dC PerFormanCe — — 1000 — — 1000 — — 1000 µF Notes: 1. guaranteed by design, not tested. 2. Output voltage for dual output models is measured at half load. 3. The “Total” specification is the maximum combined current/power of both outputs. Up to 70% of that total is available from either output provided the other output maintains a minimum of 15% of the total power used. The 15% minimum maintains regulation. 4. Effect on negative Vout from 50%/50% loads to 70%/30&% or 30%/70% loads. 5. Short circuit is measured with a 10 milliohm (±10%) resistive load. 6. Time to settle to within 1% of Vout. 7. Transition time > 10 µs 8. Tested on release from inhibit. Crane Aerospace & Electronics Power Solutions Mor single and dual dc/dc converters 28 Volt input – 120 Watt www.interpoint.com Page 12 of 24 MOR Rev K - 20100422 |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |