Electronic Components Datasheet Search
  English  ▼

X  

OPA1602AIDR Datasheet(PDF) 13 Page - Texas Instruments

Click here to check the latest version.
Part # OPA1602AIDR
Description  High-Performance, Bipolar-Input AUDIO OPERATIONAL AMPLIFIERS
PDF  23 Pages
Scroll/Zoom Zoom In 100%  Zoom Out
Manufacturer  TI1 [Texas Instruments]
Direct Link  http://www.ti.com
Logo TI1 - Texas Instruments

OPA1602AIDR Datasheet(HTML) 13 Page - Texas Instruments

Back Button OPA1602AIDR Datasheet HTML 9Page - Texas Instruments OPA1602AIDR Datasheet HTML 10Page - Texas Instruments OPA1602AIDR Datasheet HTML 11Page - Texas Instruments OPA1602AIDR Datasheet HTML 12Page - Texas Instruments OPA1602AIDR Datasheet HTML 13Page - Texas Instruments OPA1602AIDR Datasheet HTML 14Page - Texas Instruments OPA1602AIDR Datasheet HTML 15Page - Texas Instruments OPA1602AIDR Datasheet HTML 16Page - Texas Instruments OPA1602AIDR Datasheet HTML 17Page - Texas Instruments Next Button
Zoom Inzoom in Zoom Outzoom out
 13 / 23 page
background image
R
2
OPA160x
R
1
Signal Gain = 1+
Distortion Gain = 1+
R
3
V = 3V
O
RMS
Generator
Output
Analyzer
Input
Audio Precision
System Two
(1)
with PC Controller
SIGNAL
GAIN
DISTORTION
GAIN
R
1
R
2
R
3
¥
4.99kW
1kW
4.99kW
10W
49.9W
+1
-1
101
549W 4.99kW 49.9W
+10
110
101
R
2
R
1
R
2
R II R
1
3
Load
OPA1602
OPA1604
www.ti.com
SBOS474A
– APRIL 2011 – REVISED JUNE 2011
TOTAL HARMONIC DISTORTION
The validity of this technique can be verified by
MEASUREMENTS
duplicating measurements at high gain and/or high
frequency
where
the
distortion
is
within
the
The
OPA160x
series
op
amps
have
excellent
measurement
capability
of
the
test
equipment.
distortion characteristics. THD + noise is below
Measurements for this data sheet were made with an
0.00008% (G = +1, VO = 3VRMS, BW = 80kHz)
Audio
Precision
System
Two
distortion/noise
throughout the audio frequency range, 20Hz to
analyzer, which greatly simplifies such repetitive
20kHz,
with
a
2k
Ω
load
(see
Figure
7
for
measurements. The measurement technique can,
characteristic performance).
however,
be
performed
with
manual
distortion
measurement instruments.
The distortion produced by the OPA160x series op
amps is below the measurement limit of many
commercially available distortion analyzers. However,
CAPACITIVE LOADS
a special test circuit (such as Figure 35 shows) can
The dynamic characteristics of the OPA1602 and
be used to extend the measurement capabilities.
OPA1604
have
been
optimized
for
commonly
Op amp distortion can be considered an internal error
encountered gains, loads, and operating conditions.
source that can be referred to the input. Figure 35
The combination of low closed-loop gain and high
shows a circuit that causes the op amp distortion to
capacitive loads decreases the phase margin of the
be gained up (refer to the table in Figure 35 for the
amplifier and can lead to gain peaking or oscillations.
distortion gain factor for various signal gains). The
As a result, heavier capacitive loads must be isolated
addition of R3 to the otherwise standard noninverting
from the output. The simplest way to achieve this
amplifier configuration alters the feedback factor or
isolation is to add a small resistor (RS equal to 50Ω,
noise gain of the circuit. The closed-loop gain is
for example) in series with the output.
unchanged, but the feedback available for error
This small series resistor also prevents excess power
correction is reduced by the distortion gain factor,
dissipation if the output of the device becomes
thus extending the resolution by the same amount.
shorted. Figure 19 illustrates a graph of Small-Signal
Note that the input signal and load applied to the op
Overshoot vs Capacitive Load for several values of
amp are the same as with conventional feedback
RS. Also, refer to Applications Bulletin AB-028
without R3. The value of R3 should be kept small to
(literature number SBOA015, available for download
minimize its effect on the distortion measurements.
from
the
TI
web
site)
for
details
of
analysis
techniques and application circuits.
(1) For measurement bandwidth, see Figure 7 through Figure 12.
Figure 35. Distortion Test Circuit
Copyright
© 2011, Texas Instruments Incorporated
13
Product Folder Link(s): OPA1602 OPA1604



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com