2 / 5 page ![]() Only One Name Means ProTek’Tion™ www.protekdevices.com 05046.R4 12/10 Page 2 422B - 422E TyPICAL DEvICE ChARACTERISTICS MAXIMuM RATINGS @ 25°C unless Otherwise Specified PARAMETER SyMBOL vALuE uNITS Peak Operating Line Voltage V OP ±12 Volts Operating Line Current I O 200 mA Transient Voltage - 10 kV/Wire Transient Current - 8/20µs waveform - 10 kA/Wire Operating Temperature T A -55 to 100 °C Storage Temperature T STG -55 to 100 °C Response Time - < 1 ns ELECTRICAL ChARACTERISTICS PER LINE @ 25°C unless Otherwise Specified PART NuMBER MAXIMuM CLAMPING vOLTAGE (8/20µs) LINE-LINE @ 500A v C ±vOLTS MAXIMuM CLAMPING vOLTAGE (8/20µs) LINE-GND @ 500A v C ±vOLTS MAXIMuM LINE ThROuGhPuT RESISTANCE R OhMS MAXIMuM LEAKAGE CuRRENT @ 12v OP I D µA MAXIMuM CAPACITANCE @ 0v, 1Mhz C pF 422B/E 24.0 24.0 12 5 5000 INSTALLATION INSTRuCTIONS There are five (5) terminals on the LINE SIDE and five (5) terminals on the EQUIPMENT SIDE of the 422E, 4 data lines and one ground. Both grounds are connected together internally. A single low impedance is ground sufficient. Incoming data lines are cut or disconnected from the equipment to insert the 422E/B products. The incoming lines are to be connected to the line side terminals as the equipment side lines are connected to the equipment side terminals. The location of the product should be as close to the equipment as possible. The 422E/B series is designed with a short circuit failure mode to give maximum protection. A fuse, fusible link, or circuit breaker is recommended for each data/signal line on the input side for those that require an open circuit failure mode. Caution: A low DC resistance ground may not be indicative of a good lightning ground. Lightning contains a broad spectrum of frequencies up to 1 MHz. A low im- pedance path to ground at the transient frequencies is necessary. A ground strap is recommended or a #6 AWG stranded wire. For wire lengths over 1.5 meters, there may be some excessive line to earth potential under severe thunderstorm conditions. |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |