Electronic Components Datasheet Search
  English  ▼

X  

422B Datasheet(PDF) 2 Page - Protek Devices

Part # 422B
Description  DATA PROCESS LINE PROTECTOR
PDF  5 Pages
Scroll/Zoom Zoom In 100%  Zoom Out
Manufacturer  PROTEC [Protek Devices]
Direct Link  http://www.protekdevices.com
Logo PROTEC - Protek Devices

422B Datasheet(HTML) 2 Page - Protek Devices

  422B Datasheet HTML 1Page - Protek Devices 422B Datasheet HTML 2Page - Protek Devices 422B Datasheet HTML 3Page - Protek Devices 422B Datasheet HTML 4Page - Protek Devices 422B Datasheet HTML 5Page - Protek Devices  
Zoom Inzoom in Zoom Outzoom out
 2 / 5 page
background image
Only One Name Means ProTek’Tion™
www.protekdevices.com
05046.R4 12/10
Page 2
422B - 422E
TyPICAL DEvICE ChARACTERISTICS
MAXIMuM RATINGS @ 25°C unless Otherwise Specified
PARAMETER
SyMBOL
vALuE
uNITS
Peak Operating Line Voltage
V
OP
±12
Volts
Operating Line Current
I
O
200
mA
Transient Voltage
-
10
kV/Wire
Transient Current - 8/20µs waveform
-
10
kA/Wire
Operating Temperature
T
A
-55 to 100
°C
Storage Temperature
T
STG
-55 to 100
°C
Response Time
-
< 1
ns
ELECTRICAL ChARACTERISTICS PER LINE @ 25°C unless Otherwise Specified
PART
NuMBER
MAXIMuM
CLAMPING
vOLTAGE
(8/20µs)
LINE-LINE
@ 500A
v
C
±vOLTS
MAXIMuM
CLAMPING
vOLTAGE
(8/20µs)
LINE-GND
@ 500A
v
C
±vOLTS
MAXIMuM
LINE
ThROuGhPuT
RESISTANCE
R
OhMS
MAXIMuM
LEAKAGE
CuRRENT
@ 12v
OP
I
D
µA
MAXIMuM
CAPACITANCE
@ 0v, 1Mhz
C
pF
422B/E
24.0
24.0
12
5
5000
INSTALLATION INSTRuCTIONS
There are five (5) terminals on the LINE SIDE and five (5) terminals on the EQUIPMENT SIDE of the 422E, 4 data lines and one ground. Both grounds are connected
together internally. A single low impedance is ground sufficient. Incoming data lines are cut or disconnected from the equipment to insert the 422E/B products. The
incoming lines are to be connected to the line side terminals as the equipment side lines are connected to the equipment side terminals. The location of the product
should be as close to the equipment as possible. The 422E/B series is designed with a short circuit failure mode to give maximum protection. A fuse, fusible link, or
circuit breaker is recommended for each data/signal line on the input side for those that require an open circuit failure mode.
Caution: A low DC resistance ground may not be indicative of a good lightning ground. Lightning contains a broad spectrum of frequencies up to 1 MHz. A low im-
pedance path to ground at the transient frequencies is necessary. A ground strap is recommended or a #6 AWG stranded wire. For wire lengths over 1.5 meters, there
may be some excessive line to earth potential under severe thunderstorm conditions.



Html Pages

1 2 3 4 5


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp