Electronic Components Datasheet Search
  English  ▼

X  

RCP-2000 Datasheet(PDF) 2 Page - Mean Well Enterprises Co., Ltd.

Part # RCP-2000
Description  2000W Front End Power Supply
PDF  5 Pages
Scroll/Zoom Zoom In 100%  Zoom Out
Manufacturer  MEANWELL [Mean Well Enterprises Co., Ltd.]
Direct Link  http://www.meanwell.com
Logo MEANWELL - Mean Well Enterprises Co., Ltd.

RCP-2000 Datasheet(HTML) 2 Page - Mean Well Enterprises Co., Ltd.

  RCP-2000 Datasheet HTML 1Page - Mean Well Enterprises Co., Ltd. RCP-2000 Datasheet HTML 2Page - Mean Well Enterprises Co., Ltd. RCP-2000 Datasheet HTML 3Page - Mean Well Enterprises Co., Ltd. RCP-2000 Datasheet HTML 4Page - Mean Well Enterprises Co., Ltd. RCP-2000 Datasheet HTML 5Page - Mean Well Enterprises Co., Ltd.  
Zoom Inzoom in Zoom Outzoom out
 2 / 5 page
background image
MechanicalSpecification(SingleUnit)
CaseNo.974A
Unit:mm
Input/OutputConnectorPinNo. Assignment(CN501):PostronicPCIM34W13M400A1
PinNo.
PinNo.
PinNo.
PinNo.
PinNo.
PinNo.
9
1,2,3,4
13
18
23
28
33
10
11
16
15
21
20
26
25
31
30
5,6,7,8
14
19
24
29
34
12
17
22
27
32
Assignment
Assignment
Assignment
Assignment
Assignment
Assignment
MatingHousing
-V
+S
A2
SCL
+5V-AUX
AC/N
-V(signal)
+V(signal)
-S
A3
AC-OK
+12V-AUX
+V
DB
A1
SDA
FAN-FAIL
AC/L
PV
A0
A4
DC-OK
GND-AUX
DA
ON/OFF
NC
T-ALARM
FG
Postronic
PCIM34W13F400A1
direction
Airflow
41
295
1 3 5 7 9
33
2 4 6 8 10
32
34
CN501
12
13
11
15
16
14
18
19
17
21
22
20
24
25
23
27
28
26
30
31
29
SVR1
24
2000WFrontEndPowerSupply
R C P - 2 0 0 0 series
FileName:RCP-2000-SPEC2011-05-09
SAFETY STANDARDS
WITHSTANDVOLTAGE
UL60950-1, TUVEN60950-1approved
I/P-O/P:3KVACI/P-FG:1.5KVACO/P-FG:0.7KVDC
ISOLATIONRESISTANCE
MTBF
DIMENSION
PACKING
OTHERS
60.1Khrsmin.MIL-HDBK-217F(25
)
295*127*41mm(L*W*H)
SAFETY &
EMC
(Note4)
I/P-O/P,I/P-FG,O/P-FG:100MOhms/500VDC /25
/70%RH
2Kg;6pcs/13Kg/1.04CUFT
RCP-2000-12
RCP-2000-24
MODEL
RCP-2000-48
CompliancetoEN61000-4-2,3,4,5,6,8,11,EN61000-6-2(EN50082-2),heavyindustrylevel,criteria A
CompliancetoEN55022(CISPR22)ConductionClassB,RadiationClass A ;EN61000-3-2,-3
NOTE
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25
of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.
5. Derating may be needed under low input voltages. Please check the static characteristics for more details.
6. Output of all the RCP-2000 modules are connected in parallel in the rack.
7. Under parallel operation of more than one rack connecting together, ripple of the output voltage may be higher than the SPEC at light load condition.
It will go back to normal ripple level once the output load is more than 10%.
EMCIMMUNITY
EMCEMISSION



Html Pages

1 2 3 4 5


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com