| Electronic Components Datasheet Search |
|
SC1766CS08 Datasheet(PDF) 8 Page - Semtech Corporation |
|
|
|||||||||||||||||||||||||||||
SC1766CS08 Datasheet(HTML) 8 Page - Semtech Corporation |
|
8 / 11 page ![]() © 1997 SEMTECH CORP. 652 MITCHELL ROAD NEWBURY PARK CA 91320 BATTERY CHARGE CONTROLLER SC1766 Janaury 30, 1998 PRINCIPLES OF OPERATION (cont.) MODE PIN The MODE pin determines the mode in which the IC works: MODE Mode Function Floating NORMAL normal operation VDD TEST 1/512 safety timer GND AC - ∆V detector reset timer stops (not reset) The SC1766 will operate normally when the MODE pin is left floating (a 0.1µF capacitor is recom- mended to be tied to the MODE pin if the charge cir- cuit works in a noisy environment). The SC1766 oth- erwise works in the following ways if the MODE pin is biased either to VDD or to GND: A) AC Mode (MODE pin biased to GND) In the midst of normal charge operation, where the VBT pin voltage is in the range from 0.8V to 3.5V and the preset safety timer has not run out, the safety timer will stop if the MODE pin is pulled down to GND level. As long as the MODE pin remains low, the VOUT pin stays ON and the LED pin OFF re- gardless of whether the battery pack voltage de- clines (- ∆V present) or not. AC mode can be acti- vated by pulling the MODE pin to GND to avoid pre- mature battery charge cutoff due to fluctuating charge current source. Switching the MODE pin af- ter the end of the safety timer has no effect on the SC1766 display outputs, i.e., VOUT pin stays OFF while LED pin stays ON. B) TEST Mode (MODE pin biased to VDD) A unique feature of the SC1766 is that it can be put into a TEST mode by pulling the MODE pin to VDD, allowing verification tests for the SC1766 charge cir- cuit to be performed in a few tens of seconds, ex- tremely valuable in the final phase of production. When the SC1766 is in TEST mode, all the internal timers are reduced by the following factors when compared to normal operation: 1. Safety timer reduced by a factor of 512 times; 2. Initial timer reduced by a factor of 512 times; 3. Peak timer reduced by a factor of 64 times. One critical requirement needs to be observed for the OPERATION CHART OF THE SC1766 NO NO YES YES YES NO NO NO YES POWER ON IF 0.65V<VBT<3.7V V OUTgoes high for trickle charge. Safety timer and - ∆V detector reset. IF αNTCL >αNTC & αNTC >αNTCH V OUT goes high for trickle charge. - ∆V detector reset. Safety timer stops. V OUT goes low for fast charge. Safety timer starts counting. - ∆V detector & peak voltage timer start working after initial period ends. - ∆V detector & peak voltage timer working. IF αNTCL >αNTC & αNTC >αNTCH V OUT goes high for trickle charge. - ∆V detector reset. Safety timer stops. IF 0.65<VBT<3.7V V OUT goes high for trickle charge. Safety timer and - ∆V detector reset. IF Safety timer period has finished IF Peak voltage timer period has finished IF 0.25% decline of VBT is detected V OUT goes to high, fast charge finished, and trickle charge starts. NO YES YES YES NO |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |