21 / 30 page ![]() Micrel, Inc. MIC26601 July 2011 21 M9999-071311-A The process of sizing the ripple injection resistor and capacitors is: Step 1. Select Cff to feed all output ripples into the feedback pin and make sure the large time constant assumption is satisfied. Typical choice of Cff is 1nF to 100nF if R1 and R2 are in kΩ range. Step 2. Select Rinj according to the expected feedback voltage ripple using Equation 23. ) D 1 ( D f V V K SW IN ) PP ( FB DIV − × τ × × Δ = Eq. 21 Then the value of Rinj is obtained as: ⎟⎟ ⎠ ⎞ ⎜⎜ ⎝ ⎛ − × = 1 K 1 ) 2 R // 1 R ( R DIV INJ Eq. 22 Step 3. Select Cinj as 100nF, which could be considered as short for a wide range of the frequencies. Setting Output Voltage The MIC26601 requires two resistors to set the output voltage as shown in Figure 6. The output voltage is determined by Equation 23: ⎟ ⎠ ⎞ ⎜ ⎝ ⎛ + × = 2 R 1 R 1 V V FB OUT Eq. 23 where VFB = 0.8V. A typical value of R1 can be between 3kΩ and 10kΩ. If R1 is too large, it may allow noise to be introduced into the voltage feedback loop. If R1 is too small, it will decrease the efficiency of the power supply, especially at light loads. Once R1 is selected, R2 can be calculated using: FB OUT FB V V 1 R V 2 R − × = Eq. 24 Figure 6. Voltage-Divider Configuration In addition to the external ripple injection added at the FB pin, internal ripple injection is added at the inverting input of the comparator inside the MIC26601, as shown in Figure 7. The inverting input voltage VINJ is clamped to 1.2V. As VOUT is increased, the swing of VINJ will be clamped. The clamped VINJ reduces the line regulation because it is reflected as a DC error on the FB terminal. Therefore, the maximum output voltage of the MIC26601 should be limited to 5.5V to avoid this problem. Figure 7. Internal Ripple Injection Thermal Measurements Measuring the IC’s case temperature is recommended to insure it is within its operating limits. Although this might seem like a very elementary task, it is easy to get erroneous results. The most common mistake is to use the standard thermal couple that comes with a thermal meter. This thermal couple wire gauge is large, typically 22 gauge, and behaves like a heatsink, resulting in a lower case measurement. |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |