Back Button S2083 Datasheet HTML 6Page - M/A-COM Technology Solutions, Inc. S2083 Datasheet HTML 7Page - M/A-COM Technology Solutions, Inc. S2083 Datasheet HTML 8Page - M/A-COM Technology Solutions, Inc. S2083 Datasheet HTML 9Page - M/A-COM Technology Solutions, Inc. S2083 Datasheet HTML 10Page - M/A-COM Technology Solutions, Inc. S2083 Datasheet HTML 11Page - M/A-COM Technology Solutions, Inc. S2083 Datasheet HTML 12Page - M/A-COM Technology Solutions, Inc. S2083 Datasheet HTML 13Page - M/A-COM Technology Solutions, Inc. S2083 Datasheet HTML 14Page - M/A-COM Technology Solutions, Inc.  
Zoom Inzoom in Zoom Outzoom out
 13 / 14 page
background image
Surface Mount Instructions for QFN / DFN Packages
Application Note
S2083
13
Rev. V10
ADVANCED: Data Sheets contain information regarding a product M/A-COM Technology Solutions
is considering for development. Performance is based on target specifications, simulated results,
and/or prototype measurements. Commitment to develop is not guaranteed.
PRELIMINARY: Data Sheets contain information regarding a product M/A-COM Technology
Solutions has under development. Performance is based on engineering tests. Specifications are
typical. Mechanical outline has been fixed. Engineering samples and/or test data may be available.
Commitment to produce in volume is not guaranteed.
• North America Tel: 800.366.2266 • Europe Tel: +353.21.244.6400
• India Tel: +91.80.43537383
• China Tel: +86.21.2407.1588
Visit www.macomtech.com for additional data sheets and product information.
M/A-COM Technology Solutions Inc. and its affiliates reserve the right to make
changes to the product(s) or information contained herein without notice.
Table 3. Reflow Conditions
Profile Feature
Sn-Pb Eutectic Assembly
Pb-Free Assembly
Preheat/Soak
Temperature Min (Tsmin)
Temperature Max (Tsmax)
Time (ts) from (Tsmin to Tsmax)
100°C
150°C
60 - 120 seconds
150°C
200°C
60 - 120 seconds
Ramp-Up Rate
(TL to Tp)
3°C/second max.
3°C/second max.
Liquidous temperature (TL)
Time (tL) maintained above TL
183°C
60 - 150 seconds
217°C
60 - 150 seconds
Peak package body temperature (Tp)
For users Tp must not exceed the
Classification temperature in Table 4
For suppliers Tp must not exceed the
Classification temperature in Table 4
For users Tp must not exceed the
Classification temperature in Table 5
For suppliers Tp must not exceed the
Classification temperature in Table 5
Time (tp)* within 5 °C of the specified
Classification temperature (TC), see reflow
profile
20* seconds
30* seconds
Ramp-Down Rate
(Tp to TL)
6°C/second max.
6°C/second max.
Time 25°C to Peak Temperature
6 minutes max.
8 minutes max.
* Tolerance for peak profile temperature (Tp) is defined as a supplier minimum and a user maximum
Note 1: All temperatures refer to the center of the package, measured on the package body surface that is facing up during assembly reflow (e.g., live-bug). If
parts are reflowed in other than the normal live-bug assembly reflow orientation (i.e., dead-bug), Tp shall be within ± 2 °C of the live-bug Tp and still
meet the Tc requirements, otherwise, the profile shall be adjusted to achieve the latter. To accurately measure actual peak package body temperatures
refer to JEP140 for recommended thermocouple use.
Note 2: Reflow profiles in this document are for classification/preconditioning and are not meant to specify board assembly profiles. Actual board assembly
profiles should be developed based on specific process needs and board designs and should not exceed the parameters in Table 3
For example, if Tc is 260 °C and time tp is 30 seconds, this means the following for the supplier and the user.
For a supplier: The peak temperature must be at least 260 °C. The time above 255 °C must be at least 30 seconds.
For a user: The peak temperature must not exceed 260 °C. The time above 255 °C must not exceed 30 seconds.
Note 3: All components in the test load shall meet the classification profile requirements.
Note 4: SMD packages classified to a given moisture sensitivity level by using Procedures or Criteria defined within any previous version of J-STD-020,
JESD22-A112 (rescinded), IPC-SM-786 (rescinded) do not need to be reclassified to the current revision unless a change in classification level or a
higher peak classification temperature is desired.
Table 4. SnPb Eutectic Process - Classification Temperature (TC)
Package Thickness
Volume mm3 <350
Volume mm3 ≥350
<2.5 mm
235°C
220°C
≥2.5 mm
220°C
220°C



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com