Back Button ADUM1280 Datasheet HTML 8Page - Analog Devices ADUM1280 Datasheet HTML 9Page - Analog Devices ADUM1280 Datasheet HTML 10Page - Analog Devices ADUM1280 Datasheet HTML 11Page - Analog Devices ADUM1280 Datasheet HTML 12Page - Analog Devices ADUM1280 Datasheet HTML 13Page - Analog Devices ADUM1280 Datasheet HTML 14Page - Analog Devices ADUM1280 Datasheet HTML 15Page - Analog Devices ADUM1280 Datasheet HTML 16Page - Analog Devices  
Zoom Inzoom in Zoom Outzoom out
 13 / 16 page
background image
Data Sheet
ADuM1280/ADuM1281/ADuM1285/ADuM1286
Rev. 0 | Page 13 of 16
APPLICATIONS INFORMATION
PC BOARD LAYOUT
The ADuM128x digital isolator requires no external interface
circuitry for the logic interfaces. Power supply bypassing is
strongly recommended at both input and output supply pins
VDD1 and VDD2(see Figure 12). The capacitor value should be
between 0.01 µF and 0.1 µF. The total lead length between both
ends of the capacitor and the input power supply pin should not
exceed 20 mm.
The ADuM128x can readily meet CISPR 22 Class A (and
FCC Class A) emissions standards, as well as the more
stringent CISPR 22 Class B (and FCC Class B) standards in
an unshielded environment, with proper PCB design choices.
Refer to the AN-1109 Applicaton Note, Recommendations for
Control of Radiated Emissions with iCoupler Devices for PCB-
related EMI mitigation techniques, including board layout and
stack-up issues.
PROPAGATION DELAY-RELATED PARAMETERS
Propagation delay is a parameter that describes the time it takes
a logic signal to propagate through a component. The input-to-
output propagation delay time for a high-to-low transition may
differ from the propagation delay time of a low-to-high
transition.
INPUT (VIx)
OUTPUT (VOx)
tPLH
tPHL
50%
50%
Figure 12. Propagation Delay Parameters
Pulse width distortion is the maximum difference between
these two propagation delay values and an indication of how
accurately the timing of the input signal is preserved.
Channel-to-channel matching refers to the maximum amount
the propagation delay differs between channels within a single
ADuM128x component.
Propagation delay skew refers to the maximum amount the
propagation delay differs between multiple ADuM128x
components operating under the same conditions.
DC CORRECTNESS AND MAGNETIC FIELD
IMMUNITY
Positive and negative logic transitions at the isolator input
cause narrow (~1 ns) pulses to be sent via the transformer to
the decoder. The decoder is bistable and is, therefore, either set
or reset by the pulses indicating input logic transitions. In the
absence of logic transitions at the input for more than ~1.6 µs,
a periodic set of refresh pulses indicative of the correct input
state are sent to ensure dc correctness at the output.
If the decoder receives no pulses for more than about 6.4 µs, the
input side is assumed to be unpowered or nonfunctional, in which
case, the isolator output is forced to a default low state by the
watchdog timer circuit.
The limitation on the device’s magnetic field immunity is set
by the condition in which induced voltage in the transformer
receiving coil is sufficiently large to either falsely set or reset the
decoder. The following analysis defines such conditions. The
ADuM1280 is examined in a 3 V operating condition because it
represents the most susceptible mode of operation of this product.
The pulses at the transformer output have an amplitude greater
than 1.5 V. The decoder has a sensing threshold of about 1.0 V,
therefore establishing a 0.5 V margin in which induced voltages
can be tolerated. The voltage induced across the receiving coil is
given by
V = (−dβ/dt)∑πrn2; n = 1, 2, …, N
where:
β is the magnetic flux density.
rn is the radius of the nth turn in the receiving coil.
N is the number of turns in the receiving coil.
Given the geometry of the receiving coil in the ADuM1280 and
an imposed requirement that the induced voltage be, at most,
50% of the 0.5 V margin at the decoder, a maximum allowable
magnetic field is calculated, as shown in Figure 13.
MAGNETIC FIELD FREQUENCY (Hz)
100
0.001
1M
10
0.01
1k
10k
10M
0.1
1
100M
100k
Figure 13. Maximum Allowable External Magnetic Flux Density



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com