Back Button UCC28700DBVT Datasheet HTML 17Page - Texas Instruments UCC28700DBVT Datasheet HTML 18Page - Texas Instruments UCC28700DBVT Datasheet HTML 19Page - Texas Instruments UCC28700DBVT Datasheet HTML 20Page - Texas Instruments UCC28700DBVT Datasheet HTML 21Page - Texas Instruments UCC28700DBVT Datasheet HTML 22Page - Texas Instruments UCC28700DBVT Datasheet HTML 23Page - Texas Instruments UCC28700DBVT Datasheet HTML 24Page - Texas Instruments UCC28700DBVT Datasheet HTML 25Page - Texas Instruments Next Button
Zoom Inzoom in Zoom Outzoom out
 21 / 30 page
background image
UCC28700, UCC28701
UCC28702, UCC28703
www.ti.com
SLUSB41 – JULY 2012
Stand-by Power Estimate
Assuming no-load stand-by power is a critical design parameter, determine estimated no-load power based on
target converter maximum switching frequency and output power rating.
The following equation estimates the stand-by power of the converter.
(7)
For a typical USB charger application, the bias power during no-load is approximately 2.5 mW. This is based on
25-V VDD and 100-µA bias current. The output preload resistor can be estimated by VOCV and the difference in
the converter stand-by power and the bias power. The equation for output preload resistance accounts for bias
power estimated at 2.5 mW.
(8)
Typical start-up resistance values for RSTR range from 13 MΩ to 20 MΩ to achieve 1-s start-up time. The
capacitor bulk voltage for the loss estimation is the highest voltage for the stand-by power measurement,
typically 325 VDC.
(9)
For the total stand-by power estimation add an estimated 2.5 mW for snubber loss to the start-up resistance and
converter stand-by power loss.
(10)
Input Bulk Capacitance and Minimum Bulk Voltage
Determine the minimum voltage on the input capacitance, CB1 and CB2 total, in order to determine the maximum
Np to Ns turns ratio of the transformer. The input power of the converter based on target full-load efficiency,
minimum input RMS voltage, and minimum AC input frequency are used to determine the input capacitance
requirement.
Maximum input power is determined based on VOCV, IOCC, and the full-load efficiency target.
(11)
The below equation provides an accurate solution for input capacitance based on a target minimum bulk
capacitor voltage. To target a given input capacitance value, iterate the minimum capacitor voltage to achieve the
target capacitance.
(12)
Copyright © 2012, Texas Instruments Incorporated
Submit Documentation Feedback
21
Product Folder Link(s): UCC28700, UCC28701 UCC28702, UCC28703



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com