  EMPROT Datasheet HTML 1Page - rfsolutions.ltd EMPROT Datasheet HTML 2Page - rfsolutions.ltd EMPROT Datasheet HTML 3Page - rfsolutions.ltd EMPROT Datasheet HTML 4Page - rfsolutions.ltd EMPROT Datasheet HTML 5Page - rfsolutions.ltd EMPROT Datasheet HTML 6Page - rfsolutions.ltd EMPROT Datasheet HTML 7Page - rfsolutions.ltd EMPROT Datasheet HTML 8Page - rfsolutions.ltd EMPROT Datasheet HTML 9Page - rfsolutions.ltd Next Button
Zoom Inzoom in Zoom Outzoom out
 5 / 17 page
background image
ib technology
5
THE RWD HAS THREE POLLING STATES:
1) NO card present and NO host commands received.
Polling cycle rate (time between subsequent CTS low periods) is determined by the
“polling rate” parameter stored in the RWD EEPROM memory. This is typically set
to a long period (0 to 8 seconds, default setting 260mS) and is the primary means to
reduce average power consumption. This is because most of the polling cycle period is
spent in a power-down/sleep mode.
2) EM4102 card in field, NO host commands received.
When a card is detected in the field the polling rate changes to approximately 100ms
(between CTS low periods). This is to ensure that the RWD can respond quickly to the
card leaving the field and a new card being presented.
3) Host commands received and processed.
When the RWD receives commands from the host computer, the polling rate increases
to allow a quick response to the command. This means that commands such as READ
TAG can be repeated quickly with no polling delay (sleep period) between cycles.
5v
0v
Polling cycle
repeats
CTS
TTL levels
Polling cycle period set by RWD EEPROM
parameter (4ms to 8 seconds, default 1 second)
6ms
(CTS timeout)
RF OFF, Power-down/sleep period
RF ON for brief period
(to check for card)
5v
0v
Polling cycle
repeats
CTS
TTL levels
100ms polling rate
6ms (CTS timeout)
RF OFF, Power-down/sleep period
RF ON for brief period (to check for card)
100ms polling rate
Not to scale
Not to scale



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com