13 / 16 page ![]() REV. A –13– AD7751 FREQUENCY – Hz 40 –0.05 –0.10 0 0.05 0.10 0.15 0.20 0.25 0.30 45 50 55 60 65 70 Figure 11. Phase Error Between Channels (40 Hz to 70 Hz) DIGITAL-TO-FREQUENCY CONVERSION As previously described, the digital output of the low-pass filter after multiplication contains the real-power information. However, since this LPF is not an ideal “brick wall” filter implementation, the output signal also contains attenuated components at the line frequency and its harmonics, i.e., cos(h ωt) where h = 1, 2, 3, . . . etc. The magnitude response of the filter is given by: |( )| (/ . ) Hf fHz = + 1 18 9 (6) For a line frequency of 50 Hz, this would give an attenuation of the 2 ω (100 Hz) component of approximately –22 dBs. The dominating harmonic will be at twice the line frequency, i.e., cos(2 ωt) and this is due to the instantaneous power signal. Figure 12 shows the instantaneous real-power signal output of LPF which still contains a significant amount of instantaneous power information, i.e., cos(2 ωt). This signal is then passed to the digital-to-frequency converter where it is integrated (accumu- lated) over time in order to produce an output frequency. This accumulation of the signal will suppress or average out any non- dc components in the instantaneous real-power signal. The average value of a sinusoidal signal is zero. Hence the frequency generated by the AD7751 is proportional to the average real power. Figure 12 shows the digital-to-frequency conversion for steady load conditions, i.e., constant voltage and current. As can be seen in the diagram, the frequency output CF is seen to vary over time, even under steady load conditions. This fre- quency variation is primarily due to the cos(2 ωt) component in the instantaneous real-power signal. The output frequency on CF can be up to 128 times higher than the frequency on F1 and F2. This higher output frequency is generated by accumulating the instantaneous real-power signal over a much shorter time while converting it to a frequency. This shorter accumulation period means less averaging of the cos(2 ωt) component. As a conse- quence, some of this instantaneous power signal passes through the digital-to-frequency conversion. This will not be a problem in the application. Where CF is used for calibration purposes, the frequency should be averaged by the frequency counter. This will remove any ripple. If CF is being used to measure energy, e.g., in a microprocessor-based application, the CF output should also be averaged to calculate power. However, if an energy measurement is being made by counting pulses, no averaging is required. Because the outputs F1 and F2 operate at a much lower frequency, a lot more averaging of the instantaneous real- power signal is carried out. The result is a greatly attenuated sinusoidal content and a virtually ripple-free frequency output. 2 V I 2 FREQUENCY – RAD/S LPF DIGITAL-TO- FREQUENCY F1 F2 DIGITAL-TO- FREQUENCY CF INSTANTANEOUS REAL-POWER SIGNAL (FREQUENCY DOMAIN) MULTIPLIER TIME F1 CF TIME V I 0 LPF TO EXTRACT REAL POWER (DC TERM) cos(2 t) ATTENUATED BY LPF Figure 12. Real-Power-to-Frequency Conversion FAULT DETECTION The AD7751 incorporates a novel fault detection scheme that warns of fault conditions and allows the AD7751 to continue accurate billing during a fault event. The fault detection function is designed to work over a line frequency of 45 Hz to 55 Hz. The AD7751 does this by continuously monitoring both the phase and neutral (return) currents. A fault is indicated when these currents differ by more than 12.5%. However, even during a fault the output pulse rate on F1 and F2 is generated using the larger of the two currents. Because the AD7751 looks for a difference between the signals on V1A and V1B, it is important that both current transducers are closely matched. On power-up the output pulse rate of the AD7751 is proportional to the product of the signals on Channel V1A and Channel 2. If there is a difference of greater than 12.5% between V1A and V1B on power-up, the fault indicator (FAULT) will go active after about one second. In addition, if V1B is greater than V1A the AD7751 will select V1B as the input. The fault detection is automatically disabled when the voltage signal on Channel 1 is less than 0.5% of the full-scale input range. This will eliminate false detection of a fault due to noise at light loads. |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |