16 / 20 page ![]() AD8551/AD8552/AD8554 –16– REV. 0 V2 V1 VOUT R1 R3 R4 R2 AD855x IF R3 R4 = R1 R2 , THEN VOUT = R1 R2 (V1 V2) Figure 58. Using the AD855x as a Difference Amplifier In an ideal difference amplifier, the ratio of the resistors are set exactly equal to: A R R R R V == 2 1 4 3 (19) Which sets the output voltage of the system to: VA V V OUT V =− () 12 (20) Due to finite component tolerance the ratio between the four resistors will not be exactly equal, and any mismatch results in a reduction of common-mode rejection from the system. Referring to Figure 58, the exact common-mode rejection ratio can be ex- pressed as: CMRR R R RR RR RR R R = ++ − 1 4 24 23 14 2 3 2 22 (21) In the 3 op amp instrumentation amplifier configuration shown in Figure 59, the output difference amplifier is set to unity gain with all four resistors equal in value. If the tolerance of the resis- tors used in the circuit is given as δ, the worst-case CMRR of the instrumentation amplifier will be: CMRR MIN = 1 2 δ (22) VOUT R R R R AD8554-C V2 R R V1 RG AD8554-B AD8554-A VOUT = 1 + 2R RG (V1 V2) RTRIM Figure 59. A Discrete Instrumentation Amplifier Configuration Thus, using 1% tolerance resistors would result in a worst-case system CMRR of 0.02, or 34 dB. Therefore either high precision resistors or an additional trimming resistor, as shown in Figure 59, should be used to achieve high common-mode rejection. The value of this trimming resistor should be equal to the value of R multiplied by its tolerance. For example, using 10 k Ω resistors with 1% tolerance would require a series trimming resistor equal to 100 Ω. A High Accuracy Thermocouple Amplifier Figure 60 shows a K-type thermocouple amplifier configuration with cold-junction compensation. Even from a +5 V supply, the AD8551 can provide enough accuracy to achieve a resolution of better than 0.02 °C from 0°C to 500°C. D1 is used as a temperature measuring device to correct the cold-junction error from the thermocouple and should be placed as close as possible to the two terminating junctions. With the thermocouple mea- suring tip immersed in a zero-degree ice bath, R6 should be adjusted until the output is at 0 V. Using the values shown in Figure 60, the output voltage will track temperature at 10 mV/ °C. For a wider range of tempera- ture measurement, R9 can be decreased to 62 k Ω. This will create a 5 mV/ °C change at the output, allowing measurements of up to 1000 °C. AD8551 3 2 8 4 0V TO 5.00V (0 C TO 500 C) +5V 0.1 F + 10 F R9 124k R8 453 R5 40.2k R1 10.7k R2 2.74k REF02EZ 0.1 F +12V 2 6 4 ++ –– D1 1N4148 R3 53.6 R4 5.62k +5.000V K-TYPE THERMOCOUPLE 40.7 V/ C R6 200 1 Figure 60. A Precision K-Type Thermocouple Amplifier with Cold-Junction Compensation Precision Current Meter Because of its low input bias current and superb offset voltage at single supply voltages, the AD855x is an excellent amplifier for precision current monitoring. Its rail-to-rail input allows the amplifier to be used as either a high-side or low-side current monitor. Using both amplifiers in the AD8552 provides a simple method to monitor both current supply and return paths for load or fault detection. Figure 61 shows a high-side current monitor configuration. Here, the input common-mode voltage of the amplifier will be at or near the positive supply voltage. The amplifier’s rail-to-rail input provides a precise measurement even with the input common-mode voltage at the supply voltage. The CMOS input structure does not draw any input bias current, ensuring a minimum of measurement error. The 0.1 Ω resistor creates a voltage drop to the noninverting input of the AD855x. The amplifier’s output is corrected until this voltage appears at the inverting input. This creates a current through R1, which in turn flows through R2. The Monitor Output is given by: Monitor Output R R R I SENSE L =× × 2 1 (23) Using the components shown in Figure 61, the Monitor Output transfer function is 2.5 V/A. |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |