14 / 32 page ![]() REV. A AD9772A –14– can be synchronized in either mode if driven by the same reference clock, since the PLL clock multiplier when enabled ensures synchronization. RESET can be used for synchroniza- tion if the PLL clock multiplier is disabled. Figure 8 shows the proper configuration used to enable the PLL clock multiplier. In this case, the external clock source is applied to CLK+ (and/or CLK–) and the PLL clock multiplier is fully enabled by connecting PLLVDD to CLKVDD. The settling/acquisition time characteristics of the PLL are also dependent on the divide-by-N ratio as well as the input data rate. In general, the acquisition time increases with increasing data rate (for fixed divide-by-N ratio) or increasing divide-by-N ratio (for fixed input data rate). Since the VCO can operate over a 96 MHz–400 MHz range, the prescaler divide-by-ratio following the VCO must be set according to Table III for a given input data rate (i.e., fDATA) to ensure optimum phase noise and successful “locking.” In general, the best phase noise performance for any prescaler setting is achieved with the VCO operating near its maximum output frequency of 400 MHz. Note, the divide-by-N ratio also depends on whether the “zero stuffing” option is enabled since this option requires the DAC to operate at four times the input data rate. The divide-by-N ratio is set by DIV1 and DIV0. With the PLL clock multiplier enabled, PLLLOCK serves as an active HIGH control output which may be monitored upon sys- tem power-up to indicate that the PLL is successfully “locked” to the input clock. Note, when the PLL clock multiplier is NOT locked, PLLLOCK will toggle between logic HIGH and LOW in an asynchronous manner until locking is finally achieved. As a result, it is recommended that PLLLOCK, if monitored, be sampled several times to detect proper locking 100 ms upon power-up. Table III. Recommended Prescaler Divide-by-N Ratio Settings fDATA Divide-by-N (MSPS) MOD1 DIV1 DIV0 Ratio 48–160 00 01 24–100 00 12 12–50 01 04 6–25 01 18 24–100 10 01 12–50 10 12 6–25 11 04 3–12.5 1 1 1 8 As stated earlier, applications requiring input data rates below 6 MSPS must disable the PLL clock multiplier and provide an external reference clock. However, applications already contain- ing a low phase noise (i.e., jitter) reference clock that is twice (or four times) the input data rate should consider disabling the PLL clock multiplier to achieve the best SNR performance from the AD9772A. Note that the SFDR performance and wideband noise performance of the AD9772A remains unaffected with or without the PLL clock multiplier enabled. The effects of phase noise on the AD9772A’s SNR performance becomes more noticeable at higher reconstructed output fre- quencies and signal levels. Figure 9 compares the phase noise of a full-scale sine wave at exactly fDATA/4 at different data rates (hence carrier frequency) with the optimum DIV1, DIV0 setting. The effects of phase noise, and its effect on a signal’s CNR performance, becomes even more evident at higher IF fre- quencies as shown in Figure 10. In both instances, it is the “narrowband” phase noise that limits the CNR performance. FREQUENCY OFFSET – MHz 0 –10 –110 0 –30 –50 –70 –90 12 3 4 5 –100 –80 –60 –40 –20 PLL OFF, fDATA = 50MSPS PLL ON, fDATA = 50MSPS PLL ON, fDATA = 75MSPS PLL ON, fDATA = 100MSPS PLL ON, fDATA = 160MSPS Figure 9. Phase Noise of PLL Clock Multiplier at Exactly fOUT = fDATA/4 at Different fDATA Settings with Optimum DIV0/DIV1 Settings Using R & S FSEA30, RBW = 30 kHz FREQUENCY – MHz 10 –10 –110 120 –30 –50 –70 –90 122 124 126 128 130 Figure 10. Direct IF Mode Reveals Phase Noise Degrada- tion with and without PLL Clock Multiplier (IF = 125 MHz and fDATA = 100 MSPS) To disable the PLL Clock Multiplier, connect PLLVDD to PLLCOM as shown in Figure 11. LPF may remain open since this portion of the PLL circuitry is now disabled. The differen- tial clock input should be driven with a reference clock twice the data input rate in baseband applications and four times the data input rate in direct IF applications in which the “1/4 wave” mixing option is employed (i.e., MOD1 and MOD0 active HIGH). The clock distribution circuitry remains enabled pro- viding a 1 internal clock at PLLLOCK. Digital input data is |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |