PIN DESCRIPTION
Mnemonic
Function
V
DD
Power Supply Input, 5 V
± 5%.
GND
Ground Pin. Must be connected to 0 V.
A+ . . . H+
Noninverting Input to Differential Receivers
A to H.
A– . . . H–
Inverting Input to Differential Receivers A to H.
A
O .. . HO
Receiver Outputs A to H.
A through D and FS2 controls receivers
E through H.
FS1, FS2
Failsafe Control Inputs. FS1 controls receivers
A through D and FS2 control Receiver
E through H.
REV. 0
–4–
ADM5180
PIN CONFIGURATIONS
DIP
A–
A+
VDD
HO
B+
BO
FS1
GO
G+
G–
AO
B–
H+
H–
C–
FS2
C+
FO
CO
F+
D–
F–
D+
EO
DO
E+
GND
E–
13
18
1
2
28
27
5
6
7
24
23
22
3
4
26
25
8
21
9
20
10
19
11
11
12
17
16
14
15
TOP VIEW
(Not to Scale)
ADM5180
PLCC
H–
GO
FS2
FO
F+
G+
G–
B+
BO
C+
CO
D–
FS1
C–
26
27
28
4
2
3
15
18
17
16
12
14
13
25
24
21
20
19
23
22
TOP VIEW
(Not to Scale)
1
5
6
9
10
11
7
8
ADM5180
APPLICATIONS INFORMATION
FAILSAFE OPERATION
The ADM5180 provides a failsafe operating mode to guard against
input fault conditions as defined in RS-422A and RS-423A
standards. The fault conditions are (1) Driver in power-off
condition, (2) Receiver not interconnected with Driver, (3) Open-
circuited interconnecting cable, and (4) Short-circuited intercon-
necting cable. If any of these four fault conditions occurs at the
inputs of a receiver, then the output of that receiver is driven to a
known logic level. The failsafe level is programmed using the
failsafe (FS) input. There are two failsafe inputs, FS1 and FS2
which each control four receivers. FSI controls receivers A ...D
and FS2 controls receivers E . . . H. A connection to V
DD on the
failsafe input sets the output high under fault conditions while a
connection to GND sets the output low.
FS1, FS2
Output During Fault Condition
V
DD
High
GND
Low
Input Filtering
The ADM5180 contains internal low pass filtering for additional
noise rejection. Frequencies above the passband will be rejected.
For the specified input (5.5 MHz at
±500 mV) the input stage
attenuates the signal such that the threshold levels are not reached
and therefore no change of state occurs on the output. The filtering
is a function of both amplitude and and frequency. As the signal
amplitude decreases then the rejected frequency will decrease.



Html Pages

1 2 3 4 5 6


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com