| Electronic Components Datasheet Search |
|
ZPS-400AP Datasheet(PDF) 2 Page - SL Power Electronics |
|
|
|||||||||||||||||||||||||||||
ZPS-400AP Datasheet(HTML) 2 Page - SL Power Electronics |
|
2 / 2 page ![]() Condor D.C. Power Supplies, Inc., A subsidiary of SL Industries, Inc. 805-486-4565 • (800) 235-5929 Fax: (805) 487-8911 http://www.condorpower.com ZPS-150A & ZPS-200A J1-1 Enable J1-2 Output #1 Rtn ZPS-300A/AP & ZPS-400A/AP J3-1 Enable J3-2 Output #1 Rtn ZPS-150A & ZPS-200A J1-4 DC Power Good J1-3 Output #1 Rtn ZPS-300A/AP & ZPS-400A/AP J3-4 DC Power Good J3-3 Output #1 Rtn ZPS-150A & ZPS200A J2-2 Output #1 Sense+ J2-1 Output #1 Sense- ZPS-300A/AP & ZPS-400A/AP TB2-1 Output #1 Sense+ TB2-2 Output #1 Sense- AC INPUT (90-264 VAC Continuous Range Except ZPS-300A, 400A which require input jumpers to be set for 115V or 230V) FUNCTION ZPS-150A & ZPS-200A ZPS-300A, 300AP CONNECTOR ZPS-400A, 400AP 115V 230V 115V 230V SPECIFICATIONS: ALL MODELS INPUT AC Input: Auto-ranging (ZPS-150A & 200A) or Jumper selectable (ZPS-300 A & 400 A) or power factor corrected wide range (ZPS-300AP & 400AP)- input for 115 V or 230 Vac, 47-65Hz internally fused with appropriate fuses (6A-10A) Power Factor: Typical 0.99 for ZPS-300AP & 400AP. Meets EN 61000-3-2. Inrush: Cold start AC current is less than 70 A peak for one half cycle of applied power at 230 Vac, limited by a thermistor. Brownout Protection: Holds regulation to 85 Vac. Hold-up Time: 20 ms @ after removal of power at nominal line and full load. Efficiency: 70%-75% typical OUTPUT Adjustability: Output #1 is adjustable ±5%. Wide range on auxiliary outputs up to 3.3:1 (see table). Line Load Cross Regulation: ± 0.6% on all outputs, over AC input range and loads within the ranges specified in the table. Ripple & Noise: Less than 1% p-p on all outputs. Remote Sense Compensates for 250 mV total line drop. Open sense lead protection. Temperature Coefficient: 0.03% per degree C. Stability: 0.1% over 8 hours after 30 minutes warm up. Transient Response: Output voltage returns to within 1% in less than 500 µSec for a 25% load change. Peak transient does not exceed 3%. Overload Protection: All outputs protected against short circuit. Input cycling off/on is required to reset latched-off protection mode. Overvoltage Protection (Output #1): Protects against power supply induced overvoltage. Trip point is factory set so that the output does not exceed 6.4 V. Peak output Current: Peak current should be limited to a maximum of 15 seconds. Enable: TTL level ”0” or contact closure to the ve-sense line inhibits DC outputs. DC Power Good: Provides a TTL level “1” when output #1 is above 4.6 V nominal. ENVIRONMENTAL Thermal Protection: Automatic shutdown if power supply temperature exceeds 90° C. Temperature Range: 0° C to 40° C at full ratings. Output power linearly derated by 1.7% per deg. C over 50° C to 70° C. Safety Agencies: UL 1950, CSA C 22.2 234 level 5, VDE 0805 /EN 60950, CE marking to low voltage directive. Conducted EMI: All models except ZPS-300AP, meet FCC Part 15 Subpart J, Class B, VDE 0871/B, EN 55022/B. ZPS-300AP meets Class A. Output Isolation: Isolated from ground at 50 Vdc. Cooling: 5 CFM ZPS-150, 15 CFM ZPS-200, 25 CFM ZPS-300 & 300AP, 30 CFM ZPS-400, 35 CFM ZPS-400AP. Forced air required to achieve full ratings. OPTIONS: Option “C”: Available with an enclosed cover Option “M”: Intended for MEDICAL APPLICATIONS Approved to UL 544, IEC 601/VDE 0750 safety and MDS-201-0004 EMI. Leakage Current is less than 500 µA. Option “AP”: For 300 watt and 400 watt power supplies, Power Factor corrected. Consult factory for other available options. FUNCTION MODEL LOCATION NOTES CONNECTOR Output #1 ZPS-150A & ZPS-200A TB2-1 4.75V-5.25V TB-22 Rtn (Isolated) ZPS-300A/AP & 400A/AP TB4-1 4.75V-5.25V TB4-2 Rtn (Isolated) Output #2 ZPS-150A & ZPS-200A TB3-1 11.5V-25.2V TB3-2 Rtn (Isolated) ZPS-300A/AP & 400A/AP TB2-3 11.5V-25.2V TB2-4 Rtn (Isolated) Output #3 ZPS-150A & ZPS-200A TB3-3 9.5V-15.8V TB3-4 Rtn (Isolated) ZPS-300A/AP & 400A/AP TB2-5 4.75V-15.8V TB2-6 Rtn (Isolated) Output #4 ZPS-150A & ZPS-200A TB3-5 4.75V-12.6V TB3-6 Rtn (Isolated)) ZPS-300A /AP & 400A/AP TB2-7 4.75V-15.8V TB2-8 Rtn (Isolated) DC OUTPUT Barrier strip #6-32 screws 0.375” centers FUNCTION MODEL LOCATION NOTES CONNECTOR STATUS AND CONTROL Enable DC Power Good Remote Sense Dimensions: Inches Millimeters TB1-(1) TB1-(2) TB1-(3) Bus bars #8-32 screws Barrier Strip #6-32 Screws .375” centers Neutral Line 2 Line Line 1 Line Line 1 Neutral Line 2 Safety Ground Safety Ground Molex Part # 22-23-2041 Mates with Molex Part # 22-01-3047 Molex Part # 22-23-2021Mates with 22-01-3027 Barrier Strip # 6-32 Screws .375” Centers ZPS-150A, 200A 4.0 lbs - 1.8 kgs ZPS-250A, 250AP, 300A, 300AP 5.0 lbs - 2.3 kgs ZPS-400A, 400AP 7.0 lbs - 3.2 kgs 150, 200 WATTS 300, 400 WATTS (PFC AVAILABLE) 11”x 5”x 2.5” 13”x 6”x 2.5” ZPS-150A, 200A, 250A, 300A ZPS-400A |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |