| Electronic Components Datasheet Search |
|
T92 Datasheet(PDF) 3 Page - Agere Systems |
|
|
|||||||||||||||||||||||||||||
T92 Datasheet(HTML) 3 Page - Agere Systems |
|
3 / 8 page ![]() Advance Data Sheet T92-Type 10 Gbits/s 1300 nm March 2001 Uncooled DFB Laser Transmitter 3 Agere Systems Inc. Absolute Maximum Ratings Stresses in excess of the absolute maximum ratings can cause permanent damage to the device. These are abso- lute stress ratings only. Functional operation of the device is not implied at these or any other conditions in excess of those given in the operations sections of the data sheet. Exposure to absolute maximum ratings for extended periods can adversely affect device reliability. Characteristics (Minimum and maximum values specified over operating case temperature range at 50% duty cycle data signal. Typical values are measured at room temperature unless otherwise noted.) 1. With VEE connected to –5.2 V, VCC must be at 0 V; With VCC connected to +5.0V, VEE must be at 0 V. 2. Inputs are ac-coupled into an equivalent input impedance of 50 Ω. 3. Single-ended or differential operation may be used. If the inputs are driven single-ended, the unused inputs (Clock and Data) must be 50 Ω ter- minated to ground. 4. Clocked operation is normally enabled and only requires an external voltage to disable. For nonclocked operation, pin 5 must be tied to VCC. 5. With clocked operation, the optical output changes state with the rising edge of the input clock signal. The skew is measured with the rising edge of the clock centered in the middle of the data eye. 6. The transmitter is normally enabled and only requires an external voltage to disable. 7. This alarm will go active when the bias current to the laser has increased 50% or more from its beginning-of-life (BOL) value. 8. This voltage is measured from Pin 3 to VEE and is converted to laser bias current with the ratio of 20 mV/mA. 9. This voltage is measured from Pin 2 to VEE. Parameter Symbol Min Max Unit Supply Voltage VCC —5.5 V Operating Case Temperature Range TC 070 °C Storage Case Temperature Range Tstg –40 85 °C Lead Soldering Temperature/Time — — 250/10 °C/s Relative Humidity (noncondensing) RH — 85 % Minimum Fiber-Bend Radius — 1.00 (25.4) — in. (mm) Table 2. Electrical Characteristics Parameter Symbol Min Typ Max Unit dc Power Supply Voltage1 VEE –5.5/+4.75 –5.2/+5.0 –4.9/+5.25 V dc Power Supply Current Drain I — 250 400 mA Input Data/Clock Voltage: 2, 3 Single-ended Input VIN 500 700 1000 mVp-p Clocked/Nonclocked Select Voltage:4 Clocked Operation Nonclocked Operation VSEL_CLK VSEL CLK VEE VCC – 2.0 — — VEE + 0.8 VCC V V Clock/Data Input Impedance RIN —50 — Ω Clock/Data RF Return Loss (50 kHz to 10 Ghz) S11 — — –10 dB Clock/Data Input Skew5 dcSKEW –25 0 25 ps Transmitter Disable Voltage6 VDIS VCC – 2.0 — VCC V Transmitter Enable Voltage VEN VEE —VEE + 0.8 V Degrade Mode Alarm Voltage–Normal VNORMAL VCC – 2.0 — VCC V Degrade Mode Alarm Voltage–Alarmed7 VALARMED VEE —VEE + 0.8 V Laser Bias Voltage8 VB 0 500 2400 mV Back-facet Monitor Voltage (50% duty cycle)9 VBF 460 500 540 mV |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |