| Electronic Components Datasheet Search |
|
MIC24052 Datasheet(PDF) 21 Page - Micrel Semiconductor |
|
|
|||||||||||||||||||||||||||||
MIC24052 Datasheet(HTML) 21 Page - Micrel Semiconductor |
|
21 / 30 page ![]() Micrel, Inc. MIC24052 December 2012 21 M9999-120312-A Step 2. Select Rinj according to the expected feedback voltage ripple using Equation 19: D) - (1 D f V ΔV K SW IN FB(pp) div × × × = τ Eq. 21 Then the value of Rinj is obtained as: 1) K 1 ( (R1//R2) R div inj − × = Eq. 22 Step 3. Select Cinj as 100nF, which could be considered as short for a wide range of the frequencies. Setting Output Voltage The MIC24052 requires two resistors to set the output voltage as shown in Figure 9. The output voltage is determined by the equation: ) R2 R1 (1 V V FB OUT + × = Eq. 23 where, VFB = 0.8V. A typical va lue of R1 can be between 3kΩ and 10kΩ. If R1 is too large, it may allow noise to be introduced into the voltage feedback loop. If R1 is too small, it will decrease the efficiency of the power supply, especially at light loads. Once R1 is selected, R2 can be calculated using: FB OUT FB V V R1 V R2 − × = Eq. 24 Figure 9. Voltage-Divider Configuration In addition to the external ripple injection added at the FB pin, internal ripple injection is added at the inverting input of the comparator inside the MIC24052, as shown in Figure 10. The inverting input voltage VINJ is clamped to 1.2V. As VOUT is increased, the swing of VINJ will be clamped. The clamped VINJ reduces the line regulation because it is reflected as a DC error on the FB terminal. Therefore, the maximum output voltage of the MIC24052 should be limited to 5.5V to avoid this problem. Figure 10. Internal Ripple Injection Thermal Measurements Measuring the IC’s case temperature is recommended to insure it is within operating limits. Although this might seem like a very elementary task, it is easy to get erroneous results. The most common mistake is to use the standard thermal couple that comes with a thermal meter. This thermal couple wire gauge is large, typically 22 gauge, and behaves like a heatsink, resulting in a lower case measurement. Two methods of temperature measurement are using a smaller thermal couple wire or an infrared thermometer. If a thermal couple wire is used, it must be constructed of 36 gauge wire or higher then (smaller wire size) to minimize the wire heat-sinking effect. In addition, the thermal couple tip must be covered in either thermal grease or thermal glue to make sure that the thermal couple junction is making good contact with the case of the IC. Omega brand thermal couple (5SC-TT-K-36-36) is adequate for most applications. Wherever possible, an infrared thermometer is recommended. The measurement spot size of most infrared thermometers is too large for an accurate reading on a small form factor ICs. However, a IR thermometer from Optris has a 1mm spot size, which makes it a good choice for measuring the hottest point on the case. An optional stand makes it easy to hold the beam on the IC for long periods of time. |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |