2 / 3 page ![]() Altech Corp.® • 35 Royal Road • Flemington, NJ 08822-6000 • Phone (908)806-9400 • FAX (908)806-9490 • www.altechcorp.com 13 TWO POLE THREE POLE Rated Type/ Current Cat. No. Approvals 0.3A 2DU03 0.5A 2DU05 0.75A 2DU075 0.8A❶ NA 1.0A 2DU1 1.6A 2DU1.6 2.0A 2DU2 2.5A 2DU2.5 3.0A 2DU3 3.5A 2DU3.5 4.0A 2DU4 5.0A 2DU5 6.0A 2DU6 8.0A 2DU8 10A 2DU10 12A❶ NA 12.5A NA 13A 2DU13 15A❶ 2DU15 16A 2DU16 20A 2DU20 25A 2DU25 30A❶ 2DU30 32A 2DU32 * 40A 2DU40 * 50A 2DU50 * 60A❶ 2DU60 63A 2DU63 * Type/ Cat. No. Approvals 3DU03 3DU05 3DU075 NA 3DU1 3DU1.6 3DU2 3DU2.5 3DU3 3DU3.5 3DU4 3DU5 3DU6 3DU8 3DU10 NA NA 3DU13 3DU15 3DU16 3DU20 3DU25 3DU30 3DU32 * 3DU40 * 3DU50 * 3DU60 3DU63 * “D” Magnetic Trip Parameters Rated current 0.3A to 63A. 1. Hold for a minimum of 100ms at surge of 10 times rated current. 2. Trip in under 100ms at 16 times rated current. NB: Trip curves shown comply with North American standards. For trip curves according to European standards please consult Altech. 2D 3D 480Y/277VAC 0.3-60A (RC): 10kA with UL-listed RK5 back-up fuse or MCCB 0.3-10A (RC): 10kA; 13-60A (RC): 5kA no branch circuit protection required 0.3-63A (RC): 10kA 10000 ON/OFF operations❷ 40°C (104°F) 5/1.4kg (3.1 lb.) Top: 18-3 AWG; Bottom: 18-2 AWG 20 lb.in. 480Y/277VAC 0.3-60A (RC): 10kA with UL-listed RK5 back-up fuse or MCCB 0.3-10A (RC): 10kA; 13-60A (RC): 5kA no branch circuit protection required 0.3-63A (RC): 10kA 10000 ON/OFF operations❷ 40°C (104°F) 4/1.68kg (3.7 lb.) Top: 18-3 AWG; Bottom: 18-2 AWG 20 lb.in. Basic Dimensions (side view) 35 mm (1.38 in.) 70mm (2.76 in.) V-EA-D Trip 0.3A Through 10A Rated Current 1.13-1.45xI N 12 3 4 5 6 8 10 20 40 100 Multiple of Rated Current Thermal Overload “Must Trip” < 1 hr = 145% RC “Must Not Trip” > 1 hr = 113% RC 10-3 4x10-3 10-2 4x10-2 10-1 0.4 1 4 10 1 4 10 40 60 16 10-3 4x10-3 10-2 4x10-2 10-1 0.4 1 4 10 1 4 10 40 60 V-EA-D Trip 13A Through 63A Rated Current 12 3 4 5 16 68 10 20 40 100 Multiple of Rated Current Thermal Overload “Must Trip” < 1 hr = 145% RC “Must Not Trip” > 1 hr = 113% RC 1.13-1.45xI N 91.5 mm (3.60 in.) 35 mm (1.38 in.) 91.5 mm (3.60 in.) 52.5 mm (2.07 in.) UL UL UL UL UL UL UL UL UL UL UL UL UL UL UL UL UL UL UL UL UL UL UL UL UL UL UL UL UL UL UL UL UL UL UL UL UL UL UL UL UL UL UL UL UL UL UL UL |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |