Electronic Components Datasheet Search
  English  ▼

X  

DS2760AX Datasheet(PDF) 9 Page - Maxim Integrated Products

Part # DS2760AX
Description  High-Precision Li Battery Monitor
PDF  25 Pages
Scroll/Zoom Zoom In 100%  Zoom Out
Manufacturer  MAXIM [Maxim Integrated Products]
Direct Link  https://www.maximintegrated.com/en.html
Logo MAXIM - Maxim Integrated Products

DS2760AX Datasheet(HTML) 9 Page - Maxim Integrated Products

Back Button DS2760AX Datasheet HTML 5Page - Maxim Integrated Products DS2760AX Datasheet HTML 6Page - Maxim Integrated Products DS2760AX Datasheet HTML 7Page - Maxim Integrated Products DS2760AX Datasheet HTML 8Page - Maxim Integrated Products DS2760AX Datasheet HTML 9Page - Maxim Integrated Products DS2760AX Datasheet HTML 10Page - Maxim Integrated Products DS2760AX Datasheet HTML 11Page - Maxim Integrated Products DS2760AX Datasheet HTML 12Page - Maxim Integrated Products DS2760AX Datasheet HTML 13Page - Maxim Integrated Products Next Button
Zoom Inzoom in Zoom Outzoom out
 9 / 25 page
background image
DS2760
9
resistor, the DS2760 maintains the Current Accumulator in units of Volt-hours, with a resolution of
6.25
mVhrs and a full scale range of ±205 mVhrs.
The Current Accumulator is a read/write register that can be altered by the host system as needed.
CURRENT ACCUMULATOR FORMAT Figure 5
MSB—Address 10
LSb—Address 11
S
214 213 212 211 210
29
28
27
26
25
24
23
22
21
20
MSb
LSb
MSb
LSb
Units: 0.25 mAhrs for internal sense resistor
6.25
mVhrs for external sense resistor
CURRENT OFFSET COMPENSATION
Current measurement and the current accumulation are both internally compensated for offset on a
continual basis minimizing error resulting from variations in device temperature and voltage.
Additionally a constant bias may be utilized to alter any other sources of offset. This bias resides in
EEPROM address 33h in two’s-complement format and is subtracted from each current measurement.
The current offset bias is applied to both the internal and external sense resistor configurations. The
factory default for the current offset compensation is a value of 0.
CURRENT OFFSET BIAS Figure 6
Address 33
S
26
25
24
23
22
21
20
MSb
LSb
Units: 0.625 mA for internal sense resistor
15.625
mV for external sense resistor
VOLTAGE MEASUREMENT
The DS2760 continually measures the voltage between pins VIN and VSS over a range of 0 to 4.75V.
The resulting data is placed in the Voltage Register in two’s-complement format with a resolution of
4.88mV. Voltages above the maximum register value are reported as the maximum value. The Voltage
Register format is shown in Figure 7.
VOLTAGE REGISTER FORMAT Figure 7
MSB—Address 0C
LSb—Address 0D
S
29
28
27
26
25
24
23
22
21
20
X
X
X
X
X
MSb
LSb
MSb
LSb
Units: 4.88 mV



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com