37 / 48 page ![]() E2E/E2E2 Cylindrical Proximity Sensor 37 Connection to a PLC Required Conditions Connection to a PLC is possible if the specifications of the PLC and the Proximity Sensor satisfy the following conditions. (The meanings of the symbols are given below.) 1. The ON voltage of the PLC and the residual voltage of the Prox- imity Sensor must satisfy the following. V ON ≤ VCC – VR 2. The OFF current of the PLC and the leakage current of the Prox- imity Sensor must satisfy the following. I OFF ≥ Ileak (If the OFF current is not listed in the specifications, take it to be 1.3 mA.) 3. The ON current of the PLC and the control output (I OUT) of the Proximity Sensor must satisfy the following. I OUT(min) ≤ ION ≤ IOUT(max) The ON current of the PLC will vary, however, with the power sup- ply voltage and the input impedance used as shown in the follow- ing equation. I ON = (VCC – VR – )/R IN Example In this example, the above conditions are checked for when the PLC model is the C200H-ID212, the Proximity Sensor model is the E2E- X7D1-N, and the power supply voltage is 24 V. 1. V ON (14.4 V) ≤ VCC (20.4 V) – VR (3 V) = 17.4 V: OK 2. I OFF (1.3 mA) ≥ Ileak (0.8 mA): OK 3. I ON = [VCC (20.4 V) – VR (3 V) – ≈ 4.5 mA Therefore, I OUT(min) (3 mA) ≤ ION (4.5 mA): OK V ON: ON voltage of PLC (14.4 V) I ON: ON current of PLC (typ. 7 mA) I OFF: OFF current of PLC (1.3 mA) R IN: Input impedance of PLC (3 kΩ) V R: Output residual voltage of Proximity Sensor (3 V) I leak: Leakage current of Proximity Sensor (0.8 mA) I OUT: Control output of Proximity Sensor (3 to 100 mA) V CC: Power supply voltage (PLC: 20.4 to 26.4 V) Values in parentheses are for the following PLC model and Proximity Sensor model. PLC: C200H-ID212 Proximity Sensor: E2E-X7D1-N ■ Precautions for AC/DC 2-wire Proximity Sensors in Operation Connection V PC V PC (4 V)]/RIN (3 kΩ) V PC: Internal residual voltage of PLC (4 V) Model Connection type Method Description DC 2-wire AND (serial connection) The Sensors connected together must satisfy the following conditions. V S – N x VR ≥ Load operating voltage N: No. of Sensors V R: Residual voltage of each Sensor V S: Supply voltage If each Proximity Sensor is not supplied with the rated voltage and current, the indicator will not be lit properly or unnecessary pulses may be output for approximately 1 ms. OR (parallel connection) The Sensors connected together must satisfy the following conditions. N x i ≤ Load reset current N: No. of Sensors i: Leakage current of each Sensor If the MY Relay, which operates at 24 VDC, is used as a load for example, a maximum of four Proximity Sensors can be connected to the load. AC 2-wire AND (serial connection) If 100 or 200 VAC is imposed on the Proximity Sensors, V L (i.e., the voltage imposed on the load) will be obtained from the following. V L = VS – (residual voltage x No. of Proximity Sensors) (V) Therefore, if V L is lower than the load operating voltage, the load will not operate. A maximum of three Proximity Sensors can be connected in series provided that the supply voltage is 100 V minimum. Load Correct Load Correct Load Load Load Vs × 100 V Incorrect Correct |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |