Back Button E2E Datasheet HTML 24Page - Omron Electronics LLC E2E Datasheet HTML 25Page - Omron Electronics LLC E2E Datasheet HTML 26Page - Omron Electronics LLC E2E Datasheet HTML 27Page - Omron Electronics LLC E2E Datasheet HTML 28Page - Omron Electronics LLC E2E Datasheet HTML 29Page - Omron Electronics LLC E2E Datasheet HTML 30Page - Omron Electronics LLC E2E Datasheet HTML 31Page - Omron Electronics LLC E2E Datasheet HTML 32Page - Omron Electronics LLC Next Button
Zoom Inzoom in Zoom Outzoom out
 28 / 36 page
background image
28
E2E
Loads with Large Surge Currents (E2E-X
@T@)
If a load with a large surge current is connected, such as a relay, lamp, or motor, the surge current may cause the load short-circuit protection
circuit to operate, resulting in operating errors.
● Mounting
Tightening Force
Do not tighten the nut with excessive force.
A washer must be used with the nut.
Note: 1. The allowable tightening strength depends on the distance from the
edge of the head, as shown in the following table. (A is the distance
from the edge of the head. B includes the nut on the head side. If the
edge of the nut is in part A, the tightening torque for part A applies
instead.)
2. The following strengths assume washers are being used.
Refer to the following to mount the E2E-CR6, E2E-CR8 and E2E-C1
Unthreaded Cylindrical Models.
When using a set screw, tighten it to a torque of 0.2 N·m max.
(E2E-C1: 0.4 N·m max.)
Connecting a DC 2-Wire Proximity Sensor to a PLC (Programmable Controller)
Required Conditions
Connection to a PLC is possible if the specifications of the PLC and the Proximity Sensor satisfy the following
conditions. (The meanings of the symbols are given at the right.)
1. The ON voltage of the PLC and the residual voltage of the Proximity Sensor must satisfy the following.
VON
≤ VCC− VR
2. The OFF current of the PLC and the leakage current of the Proximity Sensor must satisfy the following.
IOFF
≥ Ileak
(If the OFF current is not listed in the PLC’s input specifications, take it to be 1.3 mA.)
3. The ON current of the PLC and the control output of the Proximity Sensor must satisfy the following.
IOUT (min.)
≤ ION ≤ IOUT (max.)
The ON current of the PLC will vary, however, with the power supply voltage and the input impedance, as
shown in the following equation.
ION = (VCC
− VR − VPC)/RIN
Example
In this example, the above conditions are checked when the PLC Unit is the C200H-ID212, the Proximity
Sensor is the E2E-X7D1-N, and the power supply voltage is 24 V.
1. VON (14.4 V)
≤ VCc (20.4 V) − VR (3 V) = 17.4 V:OK
2. IOFF (1.3 mA)
≥ Ileak (0.8 mA):
OK
3. ION = [VCC (20.4 V)
− VR (3 V) − VPLC (4 V)]/RIN (3 kΩ) = Approx. 4.5 mA
Therefore, IOUT (min.) (3 mA)
≤ ION (4.5 mA):
OK
Connection is thus possible.
Mutual Interference
(Unit: mm)
Note: Values in parentheses apply to Sensors operating at different frequencies.
Model
Item
M8
M12
M18
M30
DC 2-Wire Models
E2E-X
@D@
AC/DC 2-Wire Models
E2E-X
@T1
Shielded
A
20
30 (20)
50 (30)
100 (50)
B
15
20 (12)
35 (18)
70 (35)
Unshielded
A
80
120 (60)
200 (100)
300 (100)
B
60
100 (50)
110 (60)
200 (100)
DC 3-Wire Models
E2E-X
@E@/X@F@
AC 2-Wire Models
E2E-X
@Y@
Shielded
A
20
30 (20)
50 (30)
100 (50)
B
15
20 (12)
35 (18)
70 (35)
Unshielded
A
80
120 (60)
200 (100)
300 (100)
B
60
100 (50)
110 (60)
200 (100)
Model
Item
3 dia.
4 dia.
M5
5.4 dia.
DC 3-Wire Models
E2E-X
@C/B@
E2E-C
@C/B@
Shielded
A20
B15
Mutual Interference
When installing Sensors face-to-face or
side-by-side, ensure that the minimum
distances given in the following table are
maintained.
A
B
Model
Part A
Part B
Dimension
Torque
Torque
M5
1 N·m
M8
Shielded
9
9 N·m
12 N·m
Unshielded
3
M12
30 N·m
M18
70 N·m
M30
180 N·m
Part B Part A
Part B Part A
Shielded Models
Unshielded Models
8 to 21 mm
9 to 21 mm
E2E-CR8, E2E-C1
E2E-CR6
Dimpled end of
set screw (M3)
(No screws are provided
with the E2E-CR8 or
E2E-C1.)
VON: ON voltage of PLC (14.4 V)
ION: ON current of PLC (typically 7 mA)
IOFF: OFF current of PLC (1.3 mA)
RIN: Input impedance of PLC (3 k
Ω)
VPC: Internal residual voltage of PLC (4 V)
VR: Output residual voltage of Proximity Sensor
(3 V)
Ileak: Leakage current of Proximity Sensor
(0.8 mA)
IOUT Control output of Proximity Sensor (3 to
100 mA)
VCC: Power supply voltage (PLC: 20.4 to 26.4 V)
Values in parentheses apply to the following PLC
model and Proximity Sensor model.
PLC:
C200H-ID212
Sensor: E2E-X7D1-N



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com