| Electronic Components Datasheet Search |
|
E2E Datasheet(PDF) 28 Page - Omron Electronics LLC |
|
|
|||||||||||||||||||||||||||||
E2E Datasheet(HTML) 28 Page - Omron Electronics LLC |
|
28 / 36 page ![]() 28 E2E Loads with Large Surge Currents (E2E-X @T@) If a load with a large surge current is connected, such as a relay, lamp, or motor, the surge current may cause the load short-circuit protection circuit to operate, resulting in operating errors. ● Mounting Tightening Force Do not tighten the nut with excessive force. A washer must be used with the nut. Note: 1. The allowable tightening strength depends on the distance from the edge of the head, as shown in the following table. (A is the distance from the edge of the head. B includes the nut on the head side. If the edge of the nut is in part A, the tightening torque for part A applies instead.) 2. The following strengths assume washers are being used. Refer to the following to mount the E2E-CR6, E2E-CR8 and E2E-C1 Unthreaded Cylindrical Models. When using a set screw, tighten it to a torque of 0.2 N·m max. (E2E-C1: 0.4 N·m max.) Connecting a DC 2-Wire Proximity Sensor to a PLC (Programmable Controller) Required Conditions Connection to a PLC is possible if the specifications of the PLC and the Proximity Sensor satisfy the following conditions. (The meanings of the symbols are given at the right.) 1. The ON voltage of the PLC and the residual voltage of the Proximity Sensor must satisfy the following. VON ≤ VCC− VR 2. The OFF current of the PLC and the leakage current of the Proximity Sensor must satisfy the following. IOFF ≥ Ileak (If the OFF current is not listed in the PLC’s input specifications, take it to be 1.3 mA.) 3. The ON current of the PLC and the control output of the Proximity Sensor must satisfy the following. IOUT (min.) ≤ ION ≤ IOUT (max.) The ON current of the PLC will vary, however, with the power supply voltage and the input impedance, as shown in the following equation. ION = (VCC − VR − VPC)/RIN Example In this example, the above conditions are checked when the PLC Unit is the C200H-ID212, the Proximity Sensor is the E2E-X7D1-N, and the power supply voltage is 24 V. 1. VON (14.4 V) ≤ VCc (20.4 V) − VR (3 V) = 17.4 V:OK 2. IOFF (1.3 mA) ≥ Ileak (0.8 mA): OK 3. ION = [VCC (20.4 V) − VR (3 V) − VPLC (4 V)]/RIN (3 kΩ) = Approx. 4.5 mA Therefore, IOUT (min.) (3 mA) ≤ ION (4.5 mA): OK Connection is thus possible. Mutual Interference (Unit: mm) Note: Values in parentheses apply to Sensors operating at different frequencies. Model Item M8 M12 M18 M30 DC 2-Wire Models E2E-X @D@ AC/DC 2-Wire Models E2E-X @T1 Shielded A 20 30 (20) 50 (30) 100 (50) B 15 20 (12) 35 (18) 70 (35) Unshielded A 80 120 (60) 200 (100) 300 (100) B 60 100 (50) 110 (60) 200 (100) DC 3-Wire Models E2E-X @E@/X@F@ AC 2-Wire Models E2E-X @Y@ Shielded A 20 30 (20) 50 (30) 100 (50) B 15 20 (12) 35 (18) 70 (35) Unshielded A 80 120 (60) 200 (100) 300 (100) B 60 100 (50) 110 (60) 200 (100) Model Item 3 dia. 4 dia. M5 5.4 dia. DC 3-Wire Models E2E-X @C/B@ E2E-C @C/B@ Shielded A20 B15 Mutual Interference When installing Sensors face-to-face or side-by-side, ensure that the minimum distances given in the following table are maintained. A B Model Part A Part B Dimension Torque Torque M5 1 N·m M8 Shielded 9 9 N·m 12 N·m Unshielded 3 M12 30 N·m M18 70 N·m M30 180 N·m Part B Part A Part B Part A Shielded Models Unshielded Models 8 to 21 mm 9 to 21 mm E2E-CR8, E2E-C1 E2E-CR6 Dimpled end of set screw (M3) (No screws are provided with the E2E-CR8 or E2E-C1.) VON: ON voltage of PLC (14.4 V) ION: ON current of PLC (typically 7 mA) IOFF: OFF current of PLC (1.3 mA) RIN: Input impedance of PLC (3 k Ω) VPC: Internal residual voltage of PLC (4 V) VR: Output residual voltage of Proximity Sensor (3 V) Ileak: Leakage current of Proximity Sensor (0.8 mA) IOUT Control output of Proximity Sensor (3 to 100 mA) VCC: Power supply voltage (PLC: 20.4 to 26.4 V) Values in parentheses apply to the following PLC model and Proximity Sensor model. PLC: C200H-ID212 Sensor: E2E-X7D1-N |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |