| Electronic Components Datasheet Search |
|
LTC2912 Datasheet(PDF) 7 Page - Linear Technology |
|
|
|||||||||||||||||||||||||||||
LTC2912 Datasheet(HTML) 7 Page - Linear Technology |
|
7 / 12 page ![]() LTC2912 7 2912fa APPLICATIONS INFORMATION Voltage Monitoring The LTC2912 is a low power voltage monitoring circuit with an undervoltage and an overvoltage input. A timeout period that holds OV and UV asserted after a fault has cleared is adjustable using an external capacitor and may be externally disabled. When configured to monitor a posi- tive voltage Vn using the 3-resistor circuit configuration shown in Figure 1, VH will be connected to the high side tap of the resistive divider and VL will be connected to the low side tap of the resistive divider. 3-Step Design Procedure The following 3-step design procedure allows selecting appropriate resistances to obtain the desired UV and OV trip points for the voltage monitor circuit in Figure 1. For supply monitoring, Vn is the desired nominal operat- ing voltage, In is the desired nominal current through the resistive divider, VOV is the desired overvoltage trip point and VUV is the desired undervoltage trip point. 1. Choose RA to obtain the desired OV trip point RA is chosen to set the desired trip point for the overvoltage monitor. R V I V V A n n OV = 05 . • (1) 2. Choose RB to obtain the desired UV trip point Once RA is known, RB is chosen to set the desired trip point for the undervoltage monitor. R V I V V R B n n UV A = 05 . •– (2) 3. Choose RC to complete the design Once RA and RB are known, RC is determined by: R V I RR C n n AB = –– (3) If any of the variables Vn, In, VUV or VOV change, then each step must be recalculated. Voltage Monitor Example A typical voltage monitor application is shown in Figure 2. The monitored voltage is a 5V ±10% supply. Nominal cur- rent in the resistive divider is 10μA. 1. Find RA to set the OV trip point of the monitor. R V µA V V k A = ≈ 05 10 5 55 45 3 . • . . 2. Find RB to set the UV trip point of the monitor. R V µA V V kk B = ≅ 05 10 5 45 45 3 10 2 . • . –. . 3. Determine RC to complete the design. R V µA kk k C = −≈ 5 10 45 3 10 2 442 –. . Figure 1. 3-Resistor Positive UV/OV Monitoring Configuration Figure 2. Typical Supply Monitor + – 0.5V LTC2912 UV VH RC RB RA 2912 F01 Vn VL OV VH1 RC 442k RB 10.2k RA 45.3k VCC GND LTC2912-1 VL1 2912 F02 OV UV VCC 5V V1 5V ±10% |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |