13 / 35 page ![]() DP8105 5A DC-DC Intelligent dPOL Data Sheet 8V to 14V Input •••• 0.7V to 5.5V Output BCD.00261 Rev. 1.0, 12 Feb 2013 www.power-one.com Page 13 of 35 Figure 15 Transient response with non-zero Regulation. The Load Regulation parameter is an important part of Current Sharing. It is used to set one dPOL as a "master", by assigning a lower mV/A load regulation than all other dPOLs which share the load as "slaves". The dPOL with the lowest Regulation parameter sets the effective overall regulation. (See Current Sharing elsewhere in this document.) 7.2 Sequencing and Tracking Turn-on delay, turn-off delay, and rising and falling output voltage slew rates can be programmed in the dPOL Configure Sequencing window shown in Figure 16 or directly via the I2C bus by writing into the DON, DOF, and TC registers, respectively. The registers are shown in Figure 17, Figure 19, and Figure 20. Figure 16. dPOL Configure Sequencing Window 7.2.1 Turn-On Delay Turn-on delay is defined as an interval from the application of the Turn-On command until the output voltage starts ramping up. DON7 DON6 DON5 DON4 DON2 DON1 DON0 Bit 7 Bit 0 R/W-0 R/W-0 R/W-0 R/W-0 R/W-0 R/W-0 R/W-0 R/W-0 Bit 7:0 DON[7:0]: Turn-on delay time 00h: corresponds to 0ms delay after turn-on command has occurred … FFh: corresponds to 255ms delay after turn-on command has occurred DON3 Figure 17. Turn-On Delay Register DON 7.2.2 Turn-Off Delay Turn-off delay is defined as an interval from the application of the Turn-Off command until the output voltage reaches zero (if the falling slew rate is programmed) or until both high side and low side switches are turned off (if the slew rate is not programmed). Therefore, for the slew rate controlled turn-off the ramp-down time is included in the turn-off delay as shown in Figure 18. Turn-Off Command Internal ramp-down command VOUT User programmed turn-off delay, TDF Calculated delay TD Time Ramp-down time, TF Ramp-down time, T Falling slew rate dVF/dT Figure 18. Relationship between Turn-Off Delay and Falling Slew Rate As it can be seen from the figure, the internally calculated delay TD is determined by the equation below. dT dV V T T F OUT DF D − = , For proper operation TD shall be greater than zero. The appropriate value of the turn-off delay needs to be programmed to satisfy the condition. If the falling slew rate control is not utilized, the turn- off delay only determines an interval from the application of the Turn-Off command until both high side and low side switches are turned off. In this case, the output voltage ramp-down process is determined by load parameters. |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |