| Electronic Components Datasheet Search |
|
AD9786-EB Datasheet(PDF) 45 Page - Analog Devices |
|
|
|||||||||||||||||||||||||||||
AD9786-EB Datasheet(HTML) 45 Page - Analog Devices |
|
45 / 56 page ![]() AD9786 Rev. B | Page 45 of 56 DATA INPUTS Digital data inputs to the AD9786 are accessed on the evaluation board through Connector J1 and Connector J2. These are 40-pin, right-angle connectors that are intended to be used with standard ribbon cable connectors. The input level should be 3.3 V. The data format is selectable through Register 0x02, Bit 7 (DATAFMT). With this bit set to a default 0, the AD9786 assumes that the input data is in twos complement format. With this bit set to 1, data should be input in offset binary format. When the evaluation board is first powered up and the clock and data are running, it is recommended that the proper operating current be verified. Press Reset Switch SW1 to ensure that the AD9786 is in default mode. The default mode for the AD9786 is for the interpolation set to 1×. The modulator is turned off in default mode. The nominal operating currents for the evaluation board in the power-up default mode are shown in Table 39. Table 39. Nominal Operating Currents in Power-Up Default Mode Nominal Current @ Speed (mA) Evaluation Board Power Supply 50 MSPS 100 MSPS 150 MSPS 200 MSPS DVDD 26 49 74 99 CLKVDD 78 83 87 92 ACVDD/ADVDD 1 4 6 8 AVDD1 30 30 30 30 AVDD2 27 27 27 27 Table 40. SPI Registers Register Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 0 0x01 INTERP[1] INTERP[0] SERIAL PORT SW1 is a hard reset switch that sets the AD9786 to its default state. It should be used every time the AD9786 power supply is cycled, the clock is interrupted, or new data is to be written via the SPI port. Set the SPI software to read back data from the AD9786, and then verify that the expected values are read back when the software is run. ANALOG OUTPUT The analog output of the AD9786 is accessed via Connector S3. Once all settings are selected and the current levels and SPI port functionality are verified, the analog signal at S3 can be viewed. For most of the AD9786 applications, a spectrum analyzer is the preferred instrument to verify proper performance. A typical spectral plot is shown in Figure 86, with the AD9786 synthesizing a two-tone signal in the default mode with a 200 MSPS sample rate. A single-tone CW signal should provide output power of approximately +0.5 dBm to the spectrum analyzer. If the spectrum does not look correct at this point, the data input might be violating setup and hold times with respect to the input clock. To correct this, the user should vary the input data timing. If this is not possible, SPI Register 0x02, Bit 4 (DCLKPOL), can be inverted. This bit controls the clock edge upon which the data is latched. If neither of these methods corrects the spectrum, it is unlikely that the issue is timing related. In this case, verify that all instructions have been followed correctly and that the SPI port readback indicates the correct values. STOP 200MHz START 100MHz 19.9MHz/ 0 –20 –10 –40 –30 –60 –50 –80 –70 –100 –90 –110 –120 1MA A 0dBm MARKER 1 [T1] 193.00170300MHz –84.96dBm VBW SWT RBW 30kHz 560ms 30kHz UNIT RF ATT dBm 20dB REF LVL 1AVG Figure 86. Typical Spectral Plot |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |