| Electronic Components Datasheet Search |
|
CAT6201 Datasheet(PDF) 4 Page - ON Semiconductor |
|
|
|||||||||||||||||||||||||||||
CAT6201 Datasheet(HTML) 4 Page - ON Semiconductor |
|
4 / 10 page ![]() CAT6201 http://onsemi.com 4 Pin Function VIN is the supply pin for both the LDO’s operation and the load the LDO is driving. It is recommended that a 1 mF ceramic bypass capacitor be placed between the VIN pin and ground in close proximity to the device. When using longer connections to the power supply, CIN value can be increased without limit. The operating input voltage range is from 3.3 V to 13.5 V. FLT is an active low open−drain output indicating one of 3 fault conditions: 1. Input under−voltage: input is below the intended output voltage 2. Over−current. Brief over−current events are masked by a 3 ms time delay. CAT6201 will limit current anytime the load tries to draw more than the maximum allowed, however reporting of this event will occur only if the event lasts longer than the delay timer. Events terminating before the timer reaches its full count are ignored and the timer is reset. 3. Over−temperature shutdown has occurred. EN is an active HIGH logic level input for switching the regulator’s output between ON and OFF. A weak internal pull down assures that if EN pin is left open, the circuit is disabled. BYP controls the soft−start feature for the regulator. When large capacitive loads are present at the regulator’s output, enabling the regulator will produce large current surges on the VIN supply line. To reduce these surges the regulator can be turned on gently by connecting a capacitor between the BYP pin and ground. The larger the capacitance value the more slowly VOUT approaches its programmed value. The table below gives a list of common capacitor values and their resulting turn−on times. If the soft−start feature is not desired, this pin should be left floating. Capacitance [nF] tON [ms] 0 0.2 10 1 100 10 GND is the ground reference for the LDO in the TDFN package, center metal pad is internally connected to GND. If electrical contact is made with this pad, it should be to GND and/or the ground plane of the PCB. Connection to the ground plane enhances thermal conductivity drawing heat out of the package and into the surrounding PCB. ILIM stands for Current Limit and is the control input for setting the point at which the current limit is invoked. ILIM is defined as the current at which VOUT is still within 80% of its nominal value and should not be confused with ISC, the short circuit current, measured at VOUT = 0 V, which is typically 100 mA greater than ILIM. A resistor REXT placed between ILIM and GND selects the trip current according to a formula: ILIM + ILIM0 ) Current_Limit_Factor(CLF) REXT (eq. 1) ILIM0 is the built−in minimum current limit (typically 150 mA), and CLF is a numerical value (typical 30,000 Volts) which relates the allowable load current to a resistance value. The value of this resistor is determined by the following equation: REXT(W) + CLF(V) ILIM(A) * ILIM0(A) (eq. 2) It is recommended that ILIM be set to at least 50% higher than the maximum intended continuous IOUT. Example: Set ILIMIT = 600 mA REXT(W) + 30, 000 V 0.6 A * 0.15 A + 68 KW (eq. 3) VADJ is the output voltage control pin. A resistor divider placed between VOUT and GND whose center point connects to VADJ sets the LDO regulator’s output voltage. Typical VADJ value is 1.25 V. The current through the resistor divider can be anywhere between 10 mA and 1 mA. The higher this current is, the lower the noise. For best performance R1 and R2 should have similar temperature coefficients, otherwise output voltage accuracy will be compromised. VOUT + VADJ 1 ) R1 R2 (eq. 4) VOUT is the LDO regulator output. A small 2.2 mF ceramic bypass capacitor is required between VOUT and ground. For better transient response, its value can be increased to 4.7 mF. This capacitor should be located near the device. VOUT is protected against short circuits and over−temp operation by internal circuitry. In the event of an over−current, the LDO behaves like a current source, limiting current at the output. The maximum current allowed is set by REXT, the resistor between ILIM and GND. If the load attempts to draw more than the allowed current, VOUT and IOUT decrease together and thus limit the total power delivered. VOUT is protected against the application of voltages greater than VIN. For example, in automotive applications, if CAT6201 is powering a remote load and damage occurs to a wiring harness shorting a powered line, Battery + for instance, to VOUT, CAT6201 will not be damaged by this higher voltage being applied to VOUT. |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |