32 / 44 page ![]() www.ams.com/AS5030 Revision 2.4 32 - 44 AS5030 Datasheet - Application In formatio n Hys = 1. (No hysteresis) 1. Wait for CPU interrupt or delay for next angle read (typ. <3ms in LP mode, typ>3ms in ULP mode) 2. Wake up (PSM = 0) 3. Wait 0.01ms (Low Power Mode) 4. Check if Lock = 1 then read angle 5. Enable Low Power Mode or Ultra-low Power Mode (PSM=1) 6. Return to 1 The difference between Low Power Mode and Ultra-low Power Mode is the current consumption and the wake-up time to switch back to active operation. In both Reduced Power Modes, the AS5030 is inactive. The last state, e.g. the angle, AGC value, etc. is frozen and the chip starts from this frozen state when it resumes active operation. This method provides much faster start-up than a “cold start” from zero. If the AS5030 is cycled between active and reduced current mode, a substantial reduction of the average supply current can be achieved. The minimum dwelling time in active mode is the wake-up time. The actual active time depends on how much the magnet has moved while the AS5030 was in reduced power mode. The angle data is valid, when the status bit LOCK has been set. Once a valid angle has been measured, the AS5030 can be put back to reduced power mode. The average power consumption can be calculated as: (EQ 6) sampling interval = ton + toff Where: Iavg average current consumption Iactive: current consumption in active mode Ipower_down:current consumption in reduced power mode ton:time period during which the chip is operated in active mode toff: time period during which the chip is in reduced power mode Example: Ultra-low Power Mode; sampling period = one measurement every 10ms. System constants = Iactive = 14mA, Ipower_down = 30µA, ton(min) = 500µs (startup from Ultra-low Power Mode): (EQ 7) See Figure 27 for an overview table of the average current consumption in the various reduced power modes. Reducing Power Supply Peak Currents. An optional RC-filter (R1/C1) may be added to avoid peak currents in the power supply line when the AS5030 is toggled between active and reduced power mode. R1 must be chosen such that it can maintain a VDD voltage of 4.5V ~ 5.5V under all conditions, especially during long active periods when the charge on C1 has expired. C1 should be chosen such that it can support peak currents during the active operation period. For long active periods, C1 should be large and R1 should be small. Mode Current Consumption (typ.) Wake-up Time to Active Operation Active operation 14 mA 1.0 ms (without AGC) 3.8 ms (with locked AGC) Low Power Mode 1.4 mA 0.15 ms Ultra-low Power Mode 30 µA 0.5 ms off on off down power on active avg t t t I t I I + ∗ + ∗ = _ A ms s ms A s mA I avg μ μ μ μ 729 5 , 9 500 5 , 9 * 30 500 14 = + + ∗ = |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |