Back Button AS5132 Datasheet HTML 11Page - ams AG AS5132 Datasheet HTML 12Page - ams AG AS5132 Datasheet HTML 13Page - ams AG AS5132 Datasheet HTML 14Page - ams AG AS5132 Datasheet HTML 15Page - ams AG AS5132 Datasheet HTML 16Page - ams AG AS5132 Datasheet HTML 17Page - ams AG AS5132 Datasheet HTML 18Page - ams AG AS5132 Datasheet HTML 19Page - ams AG Next Button
Zoom Inzoom in Zoom Outzoom out
 15 / 27 page
background image
www.ams.com
Revision 1.4
15 - 27
AS5132
Datasheet - Detailed Descri p ti on
7.2.1 PWM External Clock
The PWM period depends on the setting of the OTP bit Ext. CLK EN. By default the internal clock source is used as a reference. An external
clock can be connected to the pin COM/INC.
In case Ext. CLK EN is set, the output-mode which is determined by the states of {COM/INC, Test3, Test2, Test1, Test0} (see Table 6) during
start-up is overwritten and U,V,W commutation mode signals are activated.
After internal power on reset (POR_en), the OTP is read out. When the Ext. CLK EN is programmed successfully, the COM/INC pin is used as
external clock for the PWM block. After 4 clock cycles of Ext. CLK EN, the reset of TADC (TADC_rst) and the PWM block is released.
Figure 14. Start-up Procedure
The reset for the PWM block is synchronized to the external PWM clock. This ensures a save reset also in case the external clock on COM/INC
is already running during start-up.
Figure 15. PWM Output Signal
Table 5. PWM Timing with Internal and External CLK Source
Symbol
Parameter
Min
Typ
Max
Unit
Note
TPWMint
PWM Period internal
600
750
900
µs
Internal clock source
TPWMext
PWM Period external
383 / CLKPWM
µs
External clock provided over
COM / INC pin
CLKPWM
Clock external mode
0
766
kHz
POR_en
system_state
Ext. CLK EN
TADC_rst
OTP_readout
RUN
258*Tclk_sys
4*Tclk_sys
Init (Error)
Zero degree
Angle Position
16 clocks
359 clocks
exit
8 clocks
T-high
T-low



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com