6 / 12 page ![]() 6 www.irf.com ARH28XXS Series 28V Input, Single Output Group A Tests V IN = 28V, CL = 0 unless otherwise specified. (continued) Test Symbol Test Conditions Group A Subgroups Limit MIN Limit MAX Units Efficiency ARH2802R5S ARH2803R3S ARH2805S ARH2805R2S ARH2812S ARH2815S ARH2802R5S ARH2803R3S ARH2805S ARH2805R2S ARH2812S ARH2815S Eff IOUT = IMAX 1 2, 3 72 75 76 76 80 80 68 68 72 72 78 78 % Power dissipation, Short circuit ARH2802R5S ARH2803R3S & ARH2805 All Others PD Short circuit across output 1, 2, 3 10 12 9.5 W Output response to step load changes Note 5 ARH2802R5S ARH2803R3S ARH2805S ARH2805R2S ARH2812S ARH2815S VTL 50% Load to/from 100% load 4, 5, 6 -200 -200 -200 -200 -300 -350 200 200 200 200 300 350 mVPK Recovery from step load changes Notes 5, 6 ARH2802R5S ARH2803R3S ARH2805S ARH2805R2S ARH2812S ARH2815S TTL 50% Load to/from 100% load 4, 5, 6 200 200 200 200 200 200 µs Turn on overshoot VOS IOUT = 10% and 100% 4, 5, 6 5.0 %Vout Turn on delay Note 7 TDLY IOUT = minimum and full rated 4, 5, 6 2.0 20 ms Isolation ISO 500VDC Input to output or any pin to case (except pin 12) 1 100 M Ω Notes to Specifications Tables 1. Paramete verified during dynamic load regulation tests. 2. Guranteed for DC to 20 MHz bandwidth. Test conducted using a 20 KHz to 2.0MHz bandwidth. 3. Deleted . 4. Output is measured for all combinations of line and load. Only the minimum and meximum readings for the ouput are recorded. 5. Load step transition time is 10 µs. 6. Recovery time is measured from the initiation of the transient to where V OUT has returned to within ±1% of its steady state value. 7. Turn on delay time is tested by application of a logical low on high transition on teh enable pin (pin 3) with power present at the input. 8. Subgroups 1 and 4 are performed at +25°C, subgroups 2 and 5 at +85°C and subgroups 3 and 6 at -55°C. |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |