Back Button RH850F1L Datasheet HTML 4Page - Renesas Technology Corp RH850F1L Datasheet HTML 5Page - Renesas Technology Corp RH850F1L Datasheet HTML 6Page - Renesas Technology Corp RH850F1L Datasheet HTML 7Page - Renesas Technology Corp RH850F1L Datasheet HTML 8Page - Renesas Technology Corp RH850F1L Datasheet HTML 9Page - Renesas Technology Corp RH850F1L Datasheet HTML 10Page - Renesas Technology Corp RH850F1L Datasheet HTML 11Page - Renesas Technology Corp RH850F1L Datasheet HTML 12Page - Renesas Technology Corp Next Button
Zoom Inzoom in Zoom Outzoom out
 8 / 16 page
background image
RH850/F1L Series E1/E20 Emulator Release Note(Restrictions when using CubeSuite+)
R20UT2743EJ0200 Rev.2.00
Page 8 of 13
Mar 20, 2014
No. 16 Regarding time measurement function
[Description]
Measurement of time in a specified range is not possible.
[Resolution]
Use measurement of time until execution stops.
No. 17 Regarding trace function(address supplement)
[Description]
Branch trace information being displayed consists of trace data on the branch origins and destinations and
complemented source code between the origins and destinations.
If the address of each branch origin has not been acquired, trace data may be indicated as invalid from the
beginning. Invalid data is displayed in the [Data] area.
[Resolution]
None
No. 18 Regarding trace function(setting of out-of-range trace event)
[Description]
For an out-of-range trace event, be sure to specify the start and end addresses.
[Resolution]
None
No. 19 Regarding trace function(section of out-of-range trace event)
[Description]
Only one section is specifiable for an out-of-range trace event.
[Resolution]
None
No. 20 Regarding trace function(abnormal exit of out-of-range trace event)
[Description]
After the emulator operation has been terminated by USB disconnection with an out-of-range trace event set,
re-connecting the emulator fails because the out-of-range trace event cannot be restored.
[Resolution]
None
No. 21 Regarding trace function(section trace/Range out trace)
[Description]
Concurrent use of “Section trace” and “Range Out trace” cannot be performed.
[Resolution]
None



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com