| Electronic Components Datasheet Search |
|
TS118 Datasheet(PDF) 4 Page - Clare, Inc. |
|
|
|||||||||||||||||||||||||||||
TS118 Datasheet(HTML) 4 Page - Clare, Inc. |
|
4 / 8 page ![]() www.clare.com 4 TS118 Rev. 4 4 PERFORMANCE DATA* *The Performance data shown in the graphs above is typical of device performance. For guaranteed parameters not indicated in the written specifications, please contact our application department. TS118 Typical LED Forward Voltage Drop (N=50 Ambient Temperature = 25 °C; IF = 5mADC) 35 30 25 20 15 10 5 0 1.17 1.19 1.21 1.23 1.25 LED Forward Voltage Drop (V) TS118 Typical On-Resistance Distribution (N=50 Ambient Temperature = 25 °C) (Load Current = 120mADC; I F = 5mADC) 35 30 25 20 15 10 5 0 25.5 27.5 29.5 31.5 26.5 28.5 30.5 ON Resistance ( Ω) TS118 Typical Blocking Voltage Distribution (N=50 Ambient Temperature = 25 °C) 35 30 25 20 15 10 5 0 357.5 387.5 417.5 447.5 372.5 402.5 432.5 Blocking Voltage (V) TS118 Typical IF for Switch Operation (N=50 Ambient Temperature = 25 °C) (Load Current = 120mADC) 0.55 0.99 1.43 0.33 0.77 1.21 1.65 LED Current (mA) 25 20 15 10 5 0 TS118 Typical IF for Switch Dropout (N=50 Ambient Temperature = 25 °C) (Load Current = 120mADC) 25 20 15 10 5 0 0.33 0.77 1.21 0.11 0.55 0.99 1.43 LED Current (mA) TS118 Typical Turn-On Time (N=50 Ambient Temperature = 25 °C) (Load Current = 120mADC; IF = 5mADC) 0.09 0.45 0.81 1.17 0.27 0.63 0.99 Turn-On (ms) 25 20 15 10 5 0 TS118 Typical Turn-Off Time (N=50 Ambient Temperature = 25 °C) (Load Current = 120mADC; IF = 5mADC) 0.27 0.63 0.99 1.35 1.17 0.81 0.45 Turn-Off (ms) 25 20 15 10 5 0 TS118 Typical Blocking Voltage vs. Temperature Temperature ( °C) -40 410 405 400 395 390 385 380 375 -20 0 20 40 60 80 100 TS118 Typical Load Current vs. Temperature Temperature ( °C) 180 160 140 120 100 80 60 40 20 0 -40 -20 0 20 40 60 80 120 100 5mA TS118 Typical Leakage vs. Temperature (Measured across Pins 7 & 8) Temperature ( °C) -40 0.045 0.040 0.035 0.030 0.025 0.020 0.015 0.010 0.005 -20 0 20 40 60 80 100 TS118 Typical Turn-On vs. Temperature (Load Current = 120mADC) Temperature ( °C) -40 0.6 0.5 0.4 0.3 0.2 0.1 0 -20 0 20 40 60 80 100 5mA TS118 Typical Turn-Off vs. Temperature (Load Current = 120mADC) Temperature ( °C) -40 1.000 0.900 0.800 0.700 0.600 0.500 0.400 0.300 0.200 0.100 0 -20 0 20 40 60 80 100 5mA 10mA 20mA |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |