  DS1305EN Datasheet HTML 1Page - Dallas Semiconductor DS1305EN Datasheet HTML 2Page - Dallas Semiconductor DS1305EN Datasheet HTML 3Page - Dallas Semiconductor DS1305EN Datasheet HTML 4Page - Dallas Semiconductor DS1305EN Datasheet HTML 5Page - Dallas Semiconductor DS1305EN Datasheet HTML 6Page - Dallas Semiconductor DS1305EN Datasheet HTML 7Page - Dallas Semiconductor DS1305EN Datasheet HTML 8Page - Dallas Semiconductor DS1305EN Datasheet HTML 9Page - Dallas Semiconductor Next Button
Zoom Inzoom in Zoom Outzoom out
 5 / 22 page
background image
DS1305
5 of 22
RTC AND RAM ADDRESS MAP
The address map for the RTC and RAM registers of the DS1305 is shown in Figure 2. Data is written to
the RTC by writing to address locations 80h to 9Fh and is written to the RAM by writing to address
locations A0h to FFh. RTC data is read by reading address locations 00h to 1Fh and RAM data is read by
reading address locations 20h to 7Fh.
ADDRESS MAP Figure 2
00H
1FH
CLOCK/CALENDAR
READ ADDRESSES ONLY
20H
7FH
96-BYTES USER RAM
READ ADDRESSES ONLY
80H
9FH
CLOCK/CALENDAR
WRITE ADDRESSES ONLY
A0H
FFH
96-BYTES USER RAM
WRITE ADDRESSES ONLY
CLOCK, CALENDAR AND ALARM
The time and calendar information is obtained by reading the appropriate register bytes. The real time
clock registers are illustrated in Figure 3. The time, calendar and alarm are set or initialized by writing
the appropriate register bytes.
Note that some bits are set to zero.
These bits will always read 0
regardless of how they are written. Also note that registers 12h to 1Fh (read) and registers 92h to 9Fh are
reserved. These registers will always read 0 regardless of how they are written. The contents of the time,
calendar and alarm registers are in the binary-coded decimal (BCD) format.
Please note that the initial power on state of all registers in not defined. Therefore it is important to
enable the oscillator (EOSC = 0) and disable write protect (WP = 0) during initial configuration.



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com