Back Button LM3642 Datasheet HTML 9Page - Texas Instruments LM3642 Datasheet HTML 10Page - Texas Instruments LM3642 Datasheet HTML 11Page - Texas Instruments LM3642 Datasheet HTML 12Page - Texas Instruments LM3642 Datasheet HTML 13Page - Texas Instruments LM3642 Datasheet HTML 14Page - Texas Instruments LM3642 Datasheet HTML 15Page - Texas Instruments LM3642 Datasheet HTML 16Page - Texas Instruments LM3642 Datasheet HTML 17Page - Texas Instruments Next Button
Zoom Inzoom in Zoom Outzoom out
 13 / 26 page
background image
SCL
SDA
data
change
allowed
data
valid
data
change
allowed
data
valid
data
change
allowed
LM3642
www.ti.com
SNVS891F – SEPTEMBER 2012 – REVISED JANUARY 2014
Under-Voltage Lockout (UVLO)
The LM3642 has an internal comparator that monitors the voltage at IN which will force the LM3642 into
shutdown if the input voltage drops to 2.8V. If the UVLO monitor threshold is tripped, the UVLO flag bit will be set
in the Flags Register. If the input voltage rises above 2.8V, the LM3642 will not be available for operation until
there is an I2C read command initiated for the Flags Register. Upon a read, the flag register will be cleared, and
normal operation can resume. This feature can be disabled by writing a ‘0’ to the UVLO EN bit in the Input
Voltage Flash Monitor Register. The mode bits in the Enable Register are cleared upon a UVLO event.
Thermal Shutdown (TSD)
When the LM3642’s die temperature reaches +150°C the boost converter shuts down, and the NFET and PFET
turn off, as does the current source (LED). When the thermal shutdown threshold is tripped, a '1' gets written to
the corresponding bit of the Flags Register (Thermal Shutdown bit), and the LM3642 will go into standby. The
LM3642 will only be allowed to restart after the Flags Register is read, clearing the fault flag. Upon restart, if the
die temperature is still above +150°C, the LM3642 will reset the fault flag and re-enter standby. The mode bits in
the Enable Register are cleared upon a TSD.
LED and/or VOUT Fault
The LED Fault flag in the Flags Register reads back a '1' if the part is active in Flash or Torch Mode and the LED
output or the VOUT node experiences short condition. The LM3642 determines an LED open condition if the OVP
threshold is crossed at the OUT pin while the device is in Flash or Torch Mode. An LED short condition is
determined if the voltage at LED goes below 500 mV (typ.) while the device is in Torch or Flash Mode. There is a
delay of 256
μs deglitch time before the LED flag is valid and 2.048 ms before the VOUT flag is valid. This delay is
the time between when the Flash or Torch current is triggered and when the LED voltage and the output voltage
is sampled. The LED flag can be reset by reading back the flags register. The mode bits in the Enable Register
are cleared upon an LED and/or VOUT fault.
I
2C-COMPATIBLE INTERFACE
DATA VALIDITY
The data on SDA line must be stable during the HIGH period of the clock signal (SCL). In other words, state of
the data line can only be changed when SCL is LOW.
Figure 22. Data Validity Diagram
A pullup resistor between the controller's VIO line and SDA must be greater than [(VIO-VOL) / 3mA] to meet the
VOL requirement on SDA. Using a larger pullup resistor results in lower switching current with slower edges, while
using a smaller pullup results in higher switching currents with faster edges.
START AND STOP CONDITIONS
START and STOP conditions classify the beginning and the end of the I2C session. A START condition is
defined as SDA signal transitioning from HIGH to LOW while SCL line is HIGH. A STOP condition is defined as
the SDA transitioning from LOW to HIGH while SCL is HIGH. The I2C master always generates START and
STOP conditions. The I2C bus is considered to be busy after a START condition and free after a STOP condition.
During data transmission, the I2C master can generate repeated START conditions. First START and repeated
START conditions are equivalent, function-wise.
Copyright © 2012–2014, Texas Instruments Incorporated
Submit Documentation Feedback
13
Product Folder Links: LM3642



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com