| Electronic Components Datasheet Search |
|
PBL386402SOS Datasheet(PDF) 13 Page - Ericsson |
|
|
|||||||||||||||||||||||||||||
PBL386402SOS Datasheet(HTML) 13 Page - Ericsson |
|
13 / 16 page ![]() PBL 386 40/2 13 Figure 12. Single-channel subscriber line interface with PBL 386 40/2 and combination CODEC/filter. RESISTORS: (Values according to IEC E96 series) R SG = 0 Ω 1% 1/10 W R LD = 49.9 k Ω 1% 1/10 W R OV = User programmable R LC = 32.4 k Ω 1% 1/10 W R REF = 49.9 k Ω 1% 1/10 W R R = 64.9 k Ω 1% 1/10 W R T = 105 k Ω 1% 1/10 W R TX = 24.9 k Ω 1% 1/10 W R B = 22.1 k Ω 1% 1/10 W R RX = 52.3 k Ω 1% 1/10 W R FB Depending on CODEC / filter R 1 = 604 k Ω 1% 1/10 W R 2 = 604 k Ω 1% 1/10 W R 3 = 249 k Ω 1% 1/10 W R 4 = 280 k Ω 1% 1/10 W R RT = 330 Ω 5% 2 W R P1, RP2 = 10 Ω 1% 1/10 W (Note 1) R F1, RF2 = Line resistor, 40 Ω 1% match CAPACITORS: (Values according to IEC E96 series) C VB = 100 nF 100 V 10% C VB2 = 150 nF 100 V 10% C VCC = 100 nF 10 V 10% C TC = 2.2 nF 100 V 10% C RC = 2.2 nF 100 V 10% C HP = 47 nF 100 V 10% C LP = 150 nF 100 V 10% C TX = 100 nF 10 V 10% C GG = 220 nF 100 V 10% C 1 = 330 nF 63 V 10% C 2 = 330 nF 63 V 10% DIODES: D VB = 1N4448 D VB2 = 1N4448 D BB = 1N4448 D HP = 1N4448 (Note 2) OVP: Secondary protection (e.g. Power Innovations TISPPBL2). The ground terminals of the secondary protection should be connected to the common ground on the Printed Board Assembly with a track as short and wide as possible, preferable a groundplane. R LC R RX R REF R LD C VCC C TX PBL 386 40/2 R TX 0 - + 0 CODEC/ Filter R FB SYSTEM CONTROL INTERFACE R R R T R B - + VCC VCC BGND TIPX VBAT VBAT2 PLC POV PLD VCC PSG NC LP DT NC DET C1 C2 RRLY HP NC RINGX AGND RSN NC REF PTG VTX DR C3 PBL 386 40/2 R OV R SG C LP C 1 R 4 C 2 R 3 C HP VB2 SLIC No. 2 etc. C RC R P2 R P1 R F2 R F1 TIP RING OVP C GG C TC VB +12 V /+5V K R C VB D VB2 C VB2 D BB VB D VB R RT E RG R 2 R 1 D HP and AGND, the overhead voltage can be set to higher values, typical values can be seen in figure 11. The R OV and corresponding V TRO (signal headroom) are typical values for THD <1% and the signal frequency 1000Hz. Observe that the 4-wire output terminal V TX can not handle more than 3,2 VPeak. So if the gain 2-wire to 4-wire is 0dB, 3,2 V Peak is maximum also for the 2-wire side. Signal levels between 3,2 and 6,4 V Peak on the 2-wire side can be handled with the PTG shorted so that the gain G 2-4S become -6,02dB. Please note that the 2-wire impedance, R R and the 4-wire to 4-wire gain has to be recalcu- lated if the PTG is shorted. Please note that the maximum signal current at the 2-wire side can not be greater than 9 mA. How to use POV: 1. Decide what overhead voltage(V TRO) is needed. The POV function is only needed if the overhead voltage exceeds 3,2 V Peak 2. In figure 11 the corresponding R OV for the decided V TRO can be found. 3. If the overhead voltage exceeds 3,2 V Peak , the G2-4S gain has to be changed to -6,02dB by connecting the PTG pin to AGND. Please note that the two-wire impedance, R R and the 4-wire to 4-wire gain has to be recalculated. Analog Temperature Guard The widely varying environmental conditions in which SLICs operate may lead to the chip temperature limitations being exceeded. The PBL 386 40/2 SLIC reduce the dc line current when approxi- mately 145 °C and increases it again automatically when the temperature drops. Accordingly transmission is not lost under high ambient temperature conditions. The detector output, DET, is forced to a logic low level when the temperature guard is active. NOTES: 1. R P1 and RP2 may be omitted if DVB is in place. 2. It is required to connect D HP between terminal HP and ground if C HP > 47nF |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |