| Electronic Components Datasheet Search |
|
LM5068 Datasheet(PDF) 11 Page - Texas Instruments |
|
|
|
|||||||||||||||||||||||||||||
LM5068 Datasheet(HTML) 11 Page - Texas Instruments |
|
11 / 30 page ![]() LM5068 www.ti.com SNVS254B – MAY 2004 – REVISED DECEMBER 2004 4. Low impedance switch to reset capacitor after initial timing delay, input under-voltage lockout, and during over-voltage and under-voltage initial timing. Current Control The LM5068 has three current sense thresholds which protect the backplane supply and circuit card from overload conditions. The voltage drop across the sense resistor (RS) is monitored at the SENSE pin. The over- current protection functions are determined through the following three distinct thresholds at the SENSE pin: 1. Circuit Breaker (CB) threshold (typically 50mV) 2. Analog Current Limit (ACL) loop threshold (typically 100mV) 3. Fast Discharge Current (FDC) threshold (typically 200mV) When the voltage drop across RS exceeds 50mV the Circuit Breaker comparator indicates an over-load condition. The TIMER sources 240µA into CT when SENSE exceeds 50mV and sinks 6µA from CT when SENSE falls below 50mV. If the CT capacitor ramps to a 4V threshold, a fault condition is declared and the gate of the MOSFET is forced low, disconnecting the power to the load. Active Current Limiting (ACL) is activated when the voltage across sense resistor RS reaches 100mV. The LM5068 controls the gate of the MOSFET and maintains a constant output load current equal to 100mV/ RS. In the ACL mode the SENSE pin is greater than 50mV and the TIMER charges CT with 240µA. A fault will be declared if the LM5068 remains in the ACL mode longer than the circuit breaker timer period. Fast Discharge Current (FDC) responds to fast rising over-loads such as short circuit faults. During a short circuit event the fast rising current may overshoot past the ACL threshold due to the finite response time of the ACL loop. If the SENSE voltage reaches 200mV a fast discharge comparator quickly pulls GATE pin low. The rapid response of the FDC circuit assures a fast and safe transition to the ACL mode. The LM5068 circuit breaker action filters low duty cycle over-load conditions to avoid declaring a fault during short duration load transients. The timer charges capacitor CT with 240µA when the SENSE voltage is greater than 50mV. When the SENSE pin voltage falls below 50mV, a 6µA current discharges the TIMER capacitor. Repetitive over-current faults with duty cycle greater than 2.5% will eventually charge CT and trip the fault timer. This feature protects the pass MOSFET which has a fast heating and slow cooling characteristic. Latch-Off and Auto-Retry If the fault conditions persist long enough for TIMER to charge CT to 4V, the LM5068 latches off (LM5068-1, -3) or switches off and initiates the re-try timer (LM5068-2, -4). At the fault condition, after reaching the 4V, the TIMER pin will continue to ramp-up with 6µA current source until it reaches the internal regulated voltage, which is equivalent to the saturation GATE drive voltage. The LM5068-1 and LM5068-3 remains off until the controller is reset by either temporarily pulling the UV pin low, pulling the TIMER pin below 1 volt, or decreasing the input voltage below the internal VDD under-voltage lockout (UVLO) threshold. The LM5068-2 and LM5068-4 respond to a fault condition by pulling the GATE and TIMER pins low and then initiating a timer sequence for automatic re-try. The re-try timer sequence begins with CT capacitor being charged slowly to 4V with a 6µA current source and then discharged quickly to 1V with a 30mA discharge current. After 8 charge/discharge cycles the GATE pin is released and charged with a 60µA current source. If the fault condition persists, the LM5068 will again turn off the MOSFET and another 8-cycle fault timer sequence will begin. Power Good Flag The power good flag (PWRGD) is activated when the MOSFET GATE is fully enhanced (>8V) and the voltage input UV and OV comparators are satisfied. The power good output is a 90V capable open drain N-Channel MOSFET. The LM5068-1 and LM5068-2 provide an active HIGH power-good state, while the LM5068-3 and LM5068–4 are configured for an active LOW power-good state. The UV comparator, OV comparator, VDD UVLO, or a circuit breaker time-out will reset the power good flag. Internal Soft-Start An internal soft-start feature ramps the (positive) input of the analog current limit amplifier during initial start-up. The ramp duration is approximately 200µs. This feature reduces the load current slew rate (di/dt) at start-up. Copyright © 2004, Texas Instruments Incorporated Submit Documentation Feedback 11 Product Folder Links: LM5068 |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |