Back Button ML22Q394 Datasheet HTML 19Page - List of Unclassifed Manufacturers ML22Q394 Datasheet HTML 20Page - List of Unclassifed Manufacturers ML22Q394 Datasheet HTML 21Page - List of Unclassifed Manufacturers ML22Q394 Datasheet HTML 22Page - List of Unclassifed Manufacturers ML22Q394 Datasheet HTML 23Page - List of Unclassifed Manufacturers ML22Q394 Datasheet HTML 24Page - List of Unclassifed Manufacturers ML22Q394 Datasheet HTML 25Page - List of Unclassifed Manufacturers ML22Q394 Datasheet HTML 26Page - List of Unclassifed Manufacturers ML22Q394 Datasheet HTML 27Page - List of Unclassifed Manufacturers Next Button
Zoom Inzoom in Zoom Outzoom out
 23 / 42 page
background image
FEDL22Q394-02
ML22Q394
23/42
FUNCTIONAL DESCRIPTION
I2C Command Interface
The I2C Interface built-in is a serial interface (: slave side) that is compliant with I2C bus specification.
It
supports Fast mode and enables data reception at 400 kbps.
The SCL and SDA pins are used to input the
command data.
Pull-up resister should be connected to SCL pin and SDA pin.
For the master on the I2C bus to communicate with this device (: slave), input the slave address with the first
seven bits after setting the start condition.
The slave address can be set using the Speech Utility.
The eighth
bit of slave address is used to set the direction (: write or read) of communication.
If the eighth bit is “0” level,
it is write mode from master to slave.
And, if the eighth bit is “1” level, it is read mode from master.
The communication is made in the unit of byte.
And acknowledge is needed for each byte.
The protocol of I2C communication is shown below.
− Command flow at data write
START condition
Slave address +W (0)
Write address
STOP condition
Data write timing
SCL
SDA
S
A6 A5 A4 A3 A2 A1 A0
A
W
D7 D6D5 D4 D3D2 D1
A
D0
A
A
Slave Address
Command Data
P
BUSYB
Status
The slave address can perform a 7-bit setup on the option screen of Speech Utility shown in figure.1.
Figure .1 The option screen of Speech Utility



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com