| Electronic Components Datasheet Search |
|
3H Datasheet(PDF) 1 Page - Tumbler Technologies + TRUMPower |
|
|
|||||||||||||||||||||||||||||
3H Datasheet(HTML) 1 Page - Tumbler Technologies + TRUMPower |
|
1 / 2 page ![]() TRUMPower 180-220 WATT POWER ADAPTERS Tumbler Technologies + TRUMPower 3350 Scott Blvd., Bldg. 13, Santa Clara, California 95054, USA Phone: 408-988-6616 ● Fax: 408-988-6622 ● email: sales@trumpower.com ● Website: www.TRUMPower.com DESCRIPTION The 3H & 3RH series of AC/DC desktop power adapters are capable of delivering 180 to 220 watts of continuous output power. They are enclosed in a 94V-1 rated polyphenylene-oxide case with an IEC320/C14 or IEC320/C6 AC inlet to mate with interchangeable cord for world-wide use. All models meet CISPR 22 and FCC class B emission limits, and comply with UL, TUV and CE requirements. FEATURES • High Effici e n c y • Ov er v o l t age protection • Short-circuit protection • O v erpo w e r p r otection • O v er temperature protec tion • Compliant w i th CEC and Energ y S t ar Efficienc y lev e l V require ment s • No load po w e r consumpt ion < 0 . 5W • Av erage activ e efficienc y ≧ 87 % • Compliant w i th RoHS req u irement s INPUT SPECIFICATIONS Input voltage: Input frequency: Input current: Touch current: 90-264 VAC 50-60 Hz 3 A (rms) for 100 VAC 1.3 A (rms) for 240 VAC 250 µA max. @ 264 VAC, 60 Hz OUTPUT SPECIFICATIONS Output voltage/current: See rating chart. Total output power: See rating chart. Ripple and noise: 380 mV peak to peak maximum Overvoltage protection: set at 112-145% of its nominal output voltage. Overcurrent protection: All models protected to short circuit conditions Temperature coefficient: All outputs ±0.04% /°C maximum Transient response: Maximum excursion of 4% or better on all models, recovering to 1% of final value within 500 us after a 25% step load change ENVIRONMENTAL SPECIFICATIONS Operating temperature: Storage temperature: Relative humidity: 0°C to +40°C -20°C to +80°C 10% to 90% non-condensing SAFETY STANDARD APPROVALS UL 60950-1, CSA C22.2 No. 60950-1 TUV EN60950-1 GENERAL SPECIFICATIONS Hold-up time: 5 ms minimum at 110 VAC or 240 VAC Efficiency: 87% minimum at full load Turn on delay time: 3 seconds maximum at 110 VAC Inrush current: No damage Withstand voltage: 1500 VAC from input to output and ground MTBF: 100,000 hours at full load at 25°C ambient, calculated per MIL-HDBK-217F EMC Performance (EN55022) EN55022: Class B conducted, class B radiated FCC: Class B conducted, class B radiated VCCI: Class B conducted, class B radiated EN61000-3-2: Harmonic distortion, class D EN61000-3-3: Line flicker EN61000-4-2: ESD, ±15 KV air and ±8 KV contact EN61000-4-3: Radiated immunity, 3 V/m EN61000-4-4: Fast transient/burst, ±1 KV EN61000-4-5: Surge, ±1 KV diff., ±2 KV com EN61000-4-6: Conducted immunity, 3 Vrms EN61000-4-8: Magnetic field immunity, 1 A/m EN61000-4-11: Voltage dip immunity, 30% reduction for 500 ms >95% reduction for 10 ms 3H & 3RH Series (LVD) RoHS |
Similar Description - 3H |
|
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |